Products & ReviewSeparations

Strata-X Polymeric SPE

Phenomenex IncAvailable: Worldwide

Robust, Accurate Polymeric Solid Phase Extraction (SPE) Products

Phenomenex Inc

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our  Product Directory.

Reviews

Average Rating 4.8

|8Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Great product

 

Average Rating 5.0

Application Area:

Organic contaminants analysis

Good local sale service, fast delivery. Reproducible and accurate results.

Review Date: 4 Sept 2023 | Phenomenex Inc

Robust, accurate and reproducible results.

 

Average Rating 5.0

Application Area:

Metabolomics

Easy to implement into the automation workflow and provides accurate and reproducible results.

Review Date: 14 Jun 2021 | Phenomenex Inc

Reproducible results with good selectivity.

 

Average Rating 4.7

Application Area:

Bioanalytical method development

Easy method development, Reproducible results, provide matrix free samples that increase selectivity of analytes.

Review Date: 17 Mar 2021 | Phenomenex Inc

Great results.

 

Average Rating 5.0

Application Area:

Bioanalysis

Cost effective, good reproducibility, and readily available.

Review Date: 19 Nov 2020 | Phenomenex Inc

Increased sensitivity.

 

Average Rating 5.0

Application Area:

Sample preparation

The cartridge delivers clean and consistent extractions using innovative sample preparation technologies for my analytical needs.

Review Date: 4 Jun 2020 | Phenomenex Inc

Great consumable!

 

Average Rating 4.7

Application Area:

PFAS purification

I use these cartridges to purifiy liquid waste and analyze PFAS. I get good results and good recoveries; the customer care is very good too. The price is competitive compared to other competitors. I reccomend this product.

Review Date: 18 Jun 2019 | Phenomenex Inc

Average Rating 4.7

Application Area:

Residue and Metabolism Chemistry

This product is excellent for cleanup of difficult matrices such as soil, tissues, and plant. The reproducibility is exceptional and the reliability is great. We make use of them consistently and have only had good results. It is a diverse column that can be use for different type of compounds.

Review Date: 30 Mar 2015 | Phenomenex Inc

Average Rating 4.3

Application Area:

Solid-phase extraction solutions

Simplified extraction, good retention capability, and applicable for neutral, acidic, or basic compounds.

Review Date: 4 Aug 2014 | Phenomenex Inc

Capitalize on cleanliness without sacrificing recovery with Strata-X polymeric SPE sorbents for solid phase extraction.

Strata-X polymeric sorbents are available in unique selectivities that have been developed to cover a diverse spectrum of analytes and simplify the method development process for fast and efficient sample preparation.

Scientific PosterSeparations

Quantitative analysis of pain panel analytes in oral fluid using microelution SPE and LC-MS/MS

In this poster, Phenomenex presents an effective sample cleanup method for oral fluid analysis. The method utilizes a mixed mode strong cation exchange Strata™-X-C microelution 96-well plate for sample cleanup and a Kinetex™ core-shell 2.6 µm Biphenyl column for fast chromatographic separation. The poster includes a representative chromatogram, linearity curves, and mutiple-reaction monitoring (MRM) transitions and linearity data for 32 pain panel analytes in oral fluid. It addresses the challenges of analyzing oral fluid samples and provides a solution using specific equipment and techniques.


Application NoteSeparations

Perfluoroalkyl Substances (PFAS) Testing Guide

Explore HPLC column choices and sample preparation options for diverse sample matrices, separation selectivities, and workflows. Download this application note to find the latest word on PFAS analysis - but certainly not the final - on this rapidly expanding field of investigation.



Application NoteSeparations

LC-MS/MS Environmental Applications

The world is changing and we need to widen our Environmental Scope. Although analytical techniques and established regulated methods are not easily changed; more complex targets, larger lists, and a variety of sample matrices create a daily challenge for environmental chemists. By using the latest technologies and techniques in HPLC/ UHPLC and Sample Preparation, laboratories and chemists are able to develop better approaches to make their work Faster, Cheaper and Easier. Phenomenex is committed to supporting the industry through a comprehensive product portfolio of Sample Preparation, HPLC/UHPLC, and LC-MS, columns and accessories, along with application and method development services to meet industry needs.


Application NoteSeparations

Clinical Sample Preparation Guide

This application note discusses sample preparation techniques for a variety of clinical samples for simplified liquid extractions (SLE) and solid phase extraction (SPE).



Application NoteSeparations

The Complete Guide to Solid Phase Extraction (SPE)

This application note gives a complete and comprehensive guide to developing your SPE method, including choosing a sorbent, pre-treatment of the sample, general starting methods for Strata-X and for Strata, industry applications and ordering information.


Application NoteSeparations

Improved Clean Up and Recovery of Pharmaceutical Compounds From Plasma

Diclofenac is a post-operative pain reliever that has also been shown to diminish the formation of the pro-inflammatory hormones. This application note describes the use of two popular extraction methods, solid phase extraction (SPE) and liquid-liquid extraction (LLE), for the isolation of diclofenac from plasma using Strata-X SPE. This article demonstrates the capability of Strata-X SPE to retain hydrophobic neutral compounds as well as acidic and basic compounds.


Application NoteSeparations

Automated SPE Method Development

Ensuring that sample extracts are clean can extend the life of costly analytical instruments, however sample preparation method development can be a laborious and time intensive process. This application note suggests how a simplified method of solid phase extraction (SPE) can be devised using a Strata-X 96-Well SPE Method Development (MD) Plate (Phenomenex) in conjunction with Tecan Freedom EVO liquid handling system.


How to advance clinical research with polymeric mixed-mode solid phase extraction

In this webinar, Dr. Stephanie Marin, Global Clinical Market Development Manager at Phenomenex, will provide a comprehensive overview of polymeric mixed-mode solid phase extraction (SPE) fundamentals and the properties of polymeric hydrophobic interaction (reversed-phase) SPE sorbents. Attendees will learn how to choose the appropriate SPE phase for their specific compounds of interest, along with an explanation of the ionic functional groups that provide the mixed-mode functionalities, including both weak and strong cation and anion exchange.

Dr. Marin will also delve into the initial extraction conditions required to initiate method development for each type of SPE sorbent, as well as specialized SPE products tailored for drug testing, phospholipid removal, and microelution SPE. This webinar will include numerous clinical research applications to exemplify these concepts.

Key learning objectives

  • Discover how to differentiate different polymeric mixed-mode SPE sorbents
  • Explore starting conditions for each sorbent type
  • Learn how to choose the best SPE sorbent for different analytes
  • Understand how to use an SPE method development plate

Who should attend?

  • Scientists doing SPE method development
  • Labratorians who want to increase their knowledge of polymeric mixed-mode SPE
  • Lab managers who want to implement SPE methods in their laboratories

Certificate of attendance
All webinar participants can request a certificate of attendance, including a learning outcomes summary, for continuing education purposes.




Product Overview

Links

Buy Strata-X Polymeric SPE Read Reviews