Myra Liquid Handling System
Bio Molecular SystemsA liquid handling system with an integrated camera with pressure based liquid level sensors which can monitor the aspirate and dispense process for errors
A liquid handling system with an integrated camera with pressure based liquid level sensors which can monitor the aspirate and dispense process for errors
An ODS column with Anion and Cation Exchange. Weak ionic ligands adequately bonded to this material optimized for the separation of basic/acidic compounds at neutral pH.
A Rapid Solid Phase Extraction (SPE) Solution

For flexible, safe and reliable laboratory automation, look no further than the innovative KX-2 collaborative laboratory robot from PAA.
The Push Cap Decapper CP600 & CP610 can cap Micronic Push Caps (i.e. Capclusters or Capmats) on 96-format tubes with internal thread in rack.
Simplify assay set up while saving on compounds, reagents and time with the new Thermo Scientific™ Multidrop™ Pico™ 1 and Pico™ 8 Digital Dispensers
Autosamplers optimized for benchtop laboratory applications
In HPLC analysis, especially in gradient elution, some unexpected peaks, which are usually called Ghost peaks, may appear in a chromatogram. Ghost peaks my appear for many reasons, including residual in injection valve, water pollution impurities and unknown components in sample. Generally, they are caused by impurities from mobile phase. Welch Ghost-Buster Column can solve this problem easily! Welch Ghost-Buster colu…
The only high-purity gas that guarantees minimal impurities.
The only high-purity gas that guarantees minimal impurities.
The only high-purity gas that guarantees minimal impurities.
The only high-purity gas that guarantees minimal impurities.
Novel Coronavirus 2019-nCoV (SARS-CoV-2) Spike Glycoprotein (S1) is a recombinant antigen which contains the Spike protein amino acids 1-674. Spike S1 protein is manufactured in HEK293 mammalian cells, ensuring the most authentic post-translational modifications.
Novel Coronavirus 2019-nCoV (SARS-CoV-2) Spike Glycoprotein (S2) is a recombinant antigen which contains the Spike S2 protein, amino acids 685-1211. Spike S2 is manufactured in mammalian HEK293 cells to ensure the most authentic post-translational modifications.
Because the column is meanly made out of silicon which is semi-conductive, a dramatic impact on the chromatographic behavior of our µPAC™ columns has been observed if no appropriate precautions are taken in case the column is connected to an ESI source of a mass spectrometer. Therefore we developed a custom made grounding cable to shunt the high voltage to ground.
The µPAC™ capLC columns are designed for increased robustness and throughput assuring sensitivity. A flow rate versatility between 1 and 15 µL/min at moderated pressures allows short gradient separations, while the µPAC™ technology ensures an exceptional high reproducibility over time and across laboratories. µPAC™ column, 50cm length, with pillar array backbone at interpillar distance of 2.5 µm, C18.
Specac offers a Short Pathlength Gas Cell that is ideal for routine gas and vapour spectroscopic analysis at room temperature, low pressures, and static or flow conditions. The cell has a fixed 10 cm pathlength, and is available in Pyrex™ and stainless steel. This Short Pathlength Gas Cell is supplied with a choice of NaCl, KBr, CaF2, BaF2, or ZnSe infrared transmission windows, and is mounted in an optical spectrometer wit…
Create more space in lab freezers and inubators with Thermo Scientific™ Nunc™ MicroWell™ MiniTrays, the optical clarity of which allows the trays to be used with inverted microscopes. Limited adsorption of proteins Lids have keyed tabs for proper orientation Large raised alphanumeric coordinates Unique surface treatment to maximize sample and reagent mixing MiniTrays for serological app…
The Endosafe ® nexgen-PTS™ is a rapid, point-of-use handheld spectrophotometer that uses USP/BET-compliant disposable cartridges for accurate, convenient, and real-time endotoxin testing, glucan concentration determination, and Gram identification. With its small benchtop footprint, the Endosafe ® nexgen-PTS™ is ideal for small to mid-size pharmaceutical companies and compounding pharmacies that want a portable, real-time t…
Integrated FAST valve and precision micro peristaltic pump
At-line cell culture media analysis. Results on 30+ components in under 10 minutes. When and where is your call. With the REBEL, now is always on the table.
The Manual Headspace Sampler allows users to perform accurate, quantitative, and repeatable static headspace analysis without the need for an expensive autosampler. The sampler can incubate up to 6 sample vials at a time, whilst also ensuring the syringe is heated to the same temperature. Adjustable timers with alarms for sampling and equilibrating times make operation simple and easy to use Applications: Volatiles…
Optimize your short path distillation and track fraction changes with this real-time molecule monitoring system
The Distek Model 2500 Dissolution System offers great flexibility and configurability. It can be configured as USP Apparatus 1, 2, 5, and 6 plus intrinsic dissolution. The extensive users, method, and reporting storage capabilities are enabled by a brilliant touch screen.