Biosafety made simple: A journey into biosafety cabinet selection and custom solutions
11 Mar 2024In the domain of laboratory safety and containment, biosafety cabinets (BSCs) serve as the primary defense against potentially dangerous materials and pathogens. Yet, it is essential to recognize that not all BSCs are alike. Every laboratory operates with its distinct research goals, procedures, and safety measures, making the one-size-fits-all approach insufficient. Customization emerges as the key to bridging this gap.
In this application eBook, we examine biosafety cabinets (BSCs) and their pivotal role in laboratory safety and efficiency. This expert guide will explore the significance of conducting thorough risk assessments before starting new experiments to determine what kind of biosafety cabinet you need before searching for a suitable vendor.
This guide will also cover:
- Custom-built biosafety cabinets
- Experimental setups
- Safety protocols
Related Products
Request Quote for All Products
LabGard ES CYTO NU-581 Class II Type A2 Biosafety Cabinet
NuAire, Inc.The LabGard CYTO NU-581 Biosafety Cabinet offers a safer environment for applications involving cytotoxic API powders through a three-tiered HEPA filtration system. Tested in extreme laboratory conditions to ensure maximum personnel, product, and environmental protection, this LabGard meets NSF/ANSI 49, EN12469, and DIN12980.

AutoLabGard ES NU-125 Mini-Room Class II, Type A2 Biosafety Cabinet
NuAire, Inc.The AutoLabGard ES (Energy Saver) NU-125 Mini-Room is designed after a Class II, Type A2 Biological Safety Cabinet on a larger scale to provide Class II protection for personnel, product, and the environment. The mini-room can be used for applications involving high-throughput robotic systems, large high-speed cell sorters, ultra-centrifuges, and laboratory equipment requiring Class II protection from potentially harmful aerosols and airborne particles. The NU-125 AutoLabGard ES is constructed with an interior stainless steel floor and wall panels that are gasketed and bolted together. Painted exterior Cold Rolled Steel (CRS) cover panels are gasketed and bolted to the stainless wall panels that make up the negative pressure plenum. Painted CRS blower modules are mounted on top of the wall panels and contain both the supply and exhaust HEPA filters along with the ultra-high efficiency DC ECM motors. Stainless steel doors complete the cabinet enclosure with a hinged window assembly mounted on each door providing an 8 inch (203mm) access opening. If additional access is needed to the interior for user or system interfaces (i.e. power/computer cables, process tubing, etc.), negative pressure pass through ports may be added to the sides or rear of the enclosure that maintain enclosure containment. The airflow pattern of the NU-125 AutoLabGard ES is identical to any class II, type A2 biosafety cabinet. Room air is pulled into the cabinet through the work access opening at an average velocity of 105 fpm (.53 m/s) to provide an air barrier. Engineered with an ultra-high efficiency motor the AutoLabGard lowers operating costs by using less electricity and increasing filter life with less heat output. Each NU-125 is tested and comes with a certified copy to tests consistent with standard NSF/ANSI 49. Contact NuAire today to start your high-throughput robotic system enclosure consultation. Example Application: A perfect match for the BD FACS Airflow Cytometer Laboratory equipment or processes requiring sterility Class II Biological Safety Cabinet protection for robotics

LabGard® ES AIR Limited NU-545 Class II, Type A2 Biosafety Cabinet
NuAire, Inc.The LabGard (Energy Saver) AIR Limited model NU-545 is an NSF/ANSI 49 certified Class II, Type A2 biological safety cabinet delivering the long-lasting, high-quality performance you and your staff demand to protect you and your work. Safety Automatic Airflow Compensation To maintain safe airflows, the LabGard Limited Edition automatically compensates for both filter loading and line voltage variance to provide you safe, constant airflow protection. HEPEX Zero Leak Airflow System The HEPEX™ Zero Leak Airflow System provides quiet, uniform velocities throughout the entire sterile work zone. All positive pressure chambers and ducts are surrounded by a vacuum or negative air pressure relative to the room. This feature eliminates the possibility of cabinet and gasket leaks. Uneven particulate loading is prevented by maintaining high-static pressure over the entire filter surface assuring True Laminar Airflow. Dynamic Air Barrier Air exchanges within a Class II, Type A2 Biological Safety Cabinet, can occur 25 times per minute. This rapid air exchange system combined with an aerodynamic, ergonomic air foil and a significantly larger access opening creates the strongest air barrier, personnel protection, of any Biological Safety Cabinet. True Laminar Airflow Unidirectional Airflow moving along parallel flow lines at a constant velocity minimizes air turbulence within the work zone. With proper techniques, activities within the work area can be performed safely minimizing the chance of cross-contamination. Technology TouchLink 2.0 Electronic Control System TouchLink™ is an easy-to-use touch screen LCD which will operate and display all system functions. On / off functions for fluorescent and germicidal ultraviolet lights, blower motor, and interior outlets. Monitors high / low limits for down flow, inflow, and sliding window position. The password protected TouchLink ™ also contains a unique date/clock display and timer functions that can be used as a laboratory timer, purge timer, outlet timer, UV light timer, auto-run timer, night setback, or weekend turn-off. TOUCHLINK™ also contains diagnostic functions for a NSF trained service technician or certifier. Real Time Airflow Monitoring Using the same technology as your NSF Accredited Certifier, model NU-545 features digital dual thermistor airflow sensors in the down flow and exhaust flow air to monitor and control real-time airflow ensuring safe airflows based on air velocity instead of pressure inside the plenum. Auto Decontamination The automatic decontamination works in conjunction with hydrogen peroxide, chlorine dioxide, and paraformaldehyde systems. The process simultaneously runs the cabinet blower at a low rate during the decontamination cycle. This will aid in the process of distributing the decontaminant gas/vapor throughout the cabinet during the entire decontamination cycle. Window clamps securely create an air tight seal against an inner window gasket. The inlet port is connected to a connection point on top of the BSC. The outlet port is attached to a fitting on an auto decontamination exhaust seal plate. Lower Total Cost of Ownership Ultra-High Efficiency Motor A single DC ECM motor with an optimally sized fan saves you up to 47% off your electricity bill compared to previously used motor technologies. LED Lighting Exterior LED lighting provides life up to 50,000 hours and is 30% more efficient than standard fluorescent lightning. The LED lighting provides cool white illumination of the work zone from 90 – 120 foot-candles (968 – 1291 lux). Larger, Longer Lasting Filters NuAire offers filters that use more filter media and offer more pleats per square inch. Combined with an ultra-high efficiency motor with more torque, a NuAire BSC can extend the life of a HEPA filter up to 10 years or more. Night Setback As a standard option, upon window closure, the NU-545 may allow the motor to continue to run at a lower rate to continually HEPA filter the work zone. The LED light will be disabled. If the sliding window is then opened, the cabinet will resume normal airflow set points in run mode. Night setback will save your facility money if your standard operating procedures require you to run the BSC 24/7. Design Monolithic Design At the core of any NuAire Biosafety Cabinet is the single piece stainless steel shell. The process starts by bending a single piece of heavy duty stainless steel to create the back and side walls of the cabinet. Additional stainless steel sheets are seam welded into place to create the top and bottom. A smaller sheet of stainless steel is bent and welded into place to create the coved interior work zone. The final step welds the frame work into place to house the motor/blower assembly and HEPA filters. The result is a monolithic shell eliminating the need for rivets, gaskets, and sealants extending product life and enhancing safety. Vibration Control The motor/blower system is suspended inside the BSC using the attenumont system, a shock absorbing technology minimizing vibration transfer from the motor to the cabinet. The HEPEX Zero Leak Airflow System uses an impermeable, antimicrobial, and flameproof flexible fabric to make up the BSC’s plenum eliminating vibration transfer from the motor/blower to the plenum. Clean-ability The interior of the BSC features smooth coved corners for easy clean-ability. A spill trough with drain valve is located under the work surface to catch any unwanted spills. The work surface comes optionally with a prop-up work tray to easily clean under the work surface.