Solid-Phase Extraction Products & Reviews

Product Filter

Field

See more

Technique

Solid-Phase Extraction
Refine your selection

Company

Search within company

Ratings

263 Products found | Selected filters:

Clear Filters
25
Best match
ProductsSeparations

Supel™ QuE Acetate Tube

Sigma-Aldrich Supelco

"QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuE Acetate Tube, pk of 50, suitable for 2007.01 per AOACDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aqueous miscible…

0.0/5.0
|0 Reviews

ProductsSeparations

Supel™ QuE PSA/C18 Tube

Sigma-Aldrich Supelco

“QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuEPSA/C18 Tube, pack of 100, suitable for 2007.01 per AOACDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aqueous miscibl…

0.0/5.0
|0 Reviews

ProductsSeparations

Supel™ QuE Citrate Extraction Tube

Sigma-Aldrich Supelco

"QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuE Citrate Extraction Tube, pk of 50, suitable for EN 15662:2008 per BSDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aq…

0.0/5.0
|0 Reviews

ProductsSeparations

SPME-LC Fiber Probe

Sigma-Aldrich Supelco

The SPME-LC fiber probes are intended as single-use devices for the extraction of small molecules out of a fluid followed by solvent desorption and LC analysis.Traditional solid phase microextraction (SPME) fibers were developed with common GC type phases, which were primarily designed for extraction of volatile or semi-volatile compounds using thermal desorption as the means of introducing sample into the chromatographic colu…

0.0/5.0
|0 Reviews

ProductsSeparations

Carboxen®/Polydimethylsiloxane (CAR/PDMS) fibers

Sigma-Aldrich Supelco

Carboxen®/Polydimethylsiloxane (CAR/PDMS) SPME FibersSolid Phase Microextraction (SPME) is an innovative, solvent-free sample prep technology that is fast, economical, and versatile. SPME uses a fiber coated with a liquid (polymer), a solid (sorbent), or a combination of both. The fiber coating removes the compounds from your sample by absorption in the case of liquid coatings or adsorbtion in the case of solid coatings. The…

0.0/5.0
|0 Reviews

ProductsSeparations

Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS) fibers

Sigma-Aldrich Supelco

Divinylbenzene/Carboxen/Polydimethylsiloxane (DVB/CAR/PDMS) SPME FibersSolid Phase Microextraction (SPME) is an innovative, solvent-free sample prep technology that is fast, economical, and versatile. SPME uses a fiber coated with a liquid (polymer), a solid (sorbent), or a combination of both. The fiber coating removes the compounds from your sample by absorption in the case of liquid coatings or adsorbtion in the case of sol…

0.0/5.0
|0 Reviews

ProductsSeparations

Polydimethylsiloxane (PDMS)- non-polar SPME Fibers

Sigma-Aldrich Supelco

Polydimethylsiloxane (PDMS)- non-polar SPME Fibers.Solid Phase Microextraction (SPME) is an innovative, solvent-free sample prep technology that is fast, economical, and versatile. SPME uses a fiber coated with a liquid (polymer), a solid (sorbent), or a combination of both. The fiber coating removes the compounds from your sample by absorption in the case of liquid coatings or adsorbtion in the case of solid coatings. The S…

0.0/5.0
|0 Reviews

ProductsSeparations

Ostro Sample Preparation Products

Waters

Ostro™ 96-well plate provides a novel solution for the cleanup of phospholipids in plasma and serum. Requiring minimal to no method development and using a simple protocol, this technology can be quickly implemented in order to optimize your laboratory's workflow. Removes significantly more phospholipids for cleaner extracts Improves reproducibility for more consistent, robust methods Increases throughput with easy-to-…

0.0/5.0
|0 Reviews

ProductsSeparations

Supelclean™ EZ-POP NP

Sigma-Aldrich Supelco

This multi-bed solid phase extraction (SPE) cartridge was designed for the extraction of non-polar persistent organic pollutants (POPs), specifically heavy and light polynuclear aromatic hydrocarbons (PAHs), from edible oil matrices such as olive and corn oil. Fatty matrix is preferentially retained by the cartridge while PAHs are washed through using acetonitrile. The resulting extract is suitable for either GC-MS or HPLC-FL…

0.0/5.0
|0 Reviews

ProductsSeparations

Supel™ QuE Z-Sep QuEChERS Tubes

Sigma-Aldrich Supelco

Supel QuE Z-Sep sorbents enhance sample cleanup for complex matrices by effectively removing more fat and color from sample extracts than traditional phases for QuEChERS. By eliminating problematic matrix interferences, Z-Sep products provide more robust LC-MS and GC-MS methods. This proprietary technology can replace C18 and PSA phases in your current methods without additional method development.Supel QuE Z-Sep/C18, a combi…

0.0/5.0
|0 Reviews

ProductsSeparations

SupelMIP® SPE - Patulin

Sigma-Aldrich Supelco

The SupelMIP SPE line consist s of highly cross-linked polymers that are engineered to extract a single analyte of interest or a class of structurally related analytes with an extremely high degree of selectivity. This is possible because selectivity is introduced during MIP synthesis in which a template molecule, designed to mimic the analyte, guides the formation of specific cavities or imprints that are sterically and chem…

0.0/5.0
|0 Reviews


ProductsSeparations

SupelMIP® SPE - Bisphenol A

Sigma-Aldrich Supelco

The SupelMIP SPE line consist s of highly cross-linked polymers that are engineered to extract a single analyte of interest or a class of structurally related analytes with an extremely high degree of selectivity. This is possible because selectivity is introduced during MIP synthesis in which a template molecule, designed to mimic the analyte, guides the formation of specific cavities or imprints that are sterically and chemi…

0.0/5.0
|0 Reviews

ProductsSeparations

SupelMIP® SPE - Aminoglycosides

Sigma-Aldrich Supelco

The SupelMIP SPE line consist s of highly cross-linked polymers that are engineered to extract a single analyte of interest or a class of structurally related analytes with an extremely high degree of selectivity. This is possible because selectivity is introduced during MIP synthesis in which a template molecule, designed to mimic the analyte, guides the formation of specific cavities or imprints that are sterically and chemi…

0.0/5.0
|0 Reviews

ProductsSeparations

Supel™ QuE

Sigma-Aldrich Supelco

Dispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products.  Using the QuEChERS method, food/agricultural samples are first extracted with an aqueous miscible solvent (e.g., acetonitrile) in the presence of high amoun…

0.0/5.0
|0 Reviews






ProductsSeparations

Presston 1000

Phenomenex Inc

Positive pressure 96-well plate sample processing with Presston 1000 offers an advanced alternative to traditional vacuum manifold processing. To offer a wider applicability, Presston 1000 is equipped for processing samples in both a low pressure setting for typical solid phase extraction steps and a high pressure setting for very viscous sample processing and for sample dry down.  In addition, Presston 1000 is compatible with…

0.0/5.0
|0 Reviews


ProductsSeparations

Pall Laboratory Manifold

Pall Life Sciences - Laboratory, Food, Beverage

A unique microbiology manifold that allows you to optimize testing without sacrificing cleanliness. With interchangeable components and coupling devices, the manifold takes direction from you. No more “dirty” manifolds: Microbial cross contamination of your sample is a thing of the past. The manifold is designed to fit most laboratory autoclaves by separating into manageable components. Double testing Capacity: A large…

0.0/5.0
|0 Reviews