Optical Imaging Contrast Agents - NiraWave™
ScinticaNiraWave optical imaging agents are novel dyes and nanomaterials ideal for the study of vascular fine structure, disease-related vascular changes and tumors.
<i>In vivo</i> imaging systems, including pre-clinical imaging systems and medical imaging systems are used to non-invasively visualize and capture images of live animals and plants. Monitor the natural processes or diseases of your subjects using small-animal pre-clinical imaging systems, including single photon positron emission tomography (SPECT), positron emission tomography (PET), computed tomography (micro-CT), magnetic resonance imaging (MRI), X-ray radiography, ultrasound, fluorescence and bioluminescence imagers. Multimodal systems and software solutions are also available for correlative analysis of organ, tissue, cell, or molecular-level processes. Find the best in vivo imaging products in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.
NiraWave optical imaging agents are novel dyes and nanomaterials ideal for the study of vascular fine structure, disease-related vascular changes and tumors.
The Alpha-SPECT mini is a high-performance SPECT imaging system for preclinical research (mice and rats). It features high performance CZT sensors providing an unparalleled energy resolution. The scanner offers an ultra-wide stationary FOV to allow for TRU whole-body dynamic scanning of both mice and rats.
Viscover PolySon L, PolySon H and PolySon T ultrasound agents are unique hard-shell ultrasound microbubbles with ideal physiological and contrast properties for all typical ultrasound methods.
There is growing demand for anesthesia equipment designed for small laboratory animals. RWD designs and manufactures complete anesthesia systems and accessories for the smallest preclinical research subjects. These systems are designed to deliver highly effective anesthesia with depth modulation. RWD systems are also designed with user safety as a priority. The system includes excellent waste gas scavenging to protect users fr…
Myelotracker® is a cutting-edge fluorescent probe that enables precise detection of neutrophils—essential immune cells—in both blood and tissue samples. It offers researchers a dependable tool for exploring inflammation, infections, and immune system activity.
Phantech has developed the Bio-Mouse™; the first fillable biomimetic mouse phantom with Computed Tomography (CT) Hounsfield Unit (HU) density-equivalent bone and soft tissue.
The DELab micro computed tomography-100 (µCT-100) is designed specifically for in vivo imaging of small laboratory animals and ex vivo isolated samples. Research applications of the system range from musculoskeletal and metabolic disease, oncology, drug/therapeutic development, cardiology, anatomy, food science, and geology.
Viscover provides the broadest portfolio of imaging agents tailored for your pre-clinical micro-CT studies.
The Prodigy is a compact, high-performance ultrasound system optimized for a variety of ultrasound engineering research applications. There are 2 available configurations within the Prodigy architecture: one with 256 transmit/receive channels that supports multiplexing up to 512 transducer channels, and the other one with 128 transmit/receive channels.
Imalytics Preclinical is a software for fast interactive segmentation, reconstruction, 3D visualization, and analysis of biomedical image data sets with a user-friendly interface. It supports 3D, 4D, and 5D image data from any modality if the file format is supported. It has been used to analyze (multimodal) data sets from CT, PET, SPECT, MRI, US, FLT, and BLT.
The USphere Series of microbubble contrast agents have been specifically designed for use in a variety of species used in preclinical research, anywhere from mice, rats, rabbits and even pigs; and have been tested and shown to work effectively at frequencies from 1 to 40MHz. Specifically, these agents have been tested on our Prospect T1 high frequency ultrasound system and have been found to perform well with both linear and h…
Dedicated product portfolio of animal imaging agents that will unleash the full potential of preclinical animal MRI, employing innovative agents from small molecules to nanoparticles.
Scintica’s micro PVC phantoms are available in 3 sizes (27 mm OD, 34 mm OD, and 49 mm OD). These phantoms consist of one custom manufactured component and three separate pieces of commercial hardware for assembly. They have three separate voids, one with a series of spheres for a contrast recovery curve, one with a separately fillable warm background, and a final separate reference volume that can be optionally filled.
"Derenzo" phantoms are used to characterize an imaging system's resolution by measuring the FWHM of hole patterns with varying diameters and spacing. Holes within a size group are spaced at exactly 2D (twice the diameter) apart. Our Derenzo phantoms feature six different hole sizes arranged in triangles around the center of phantom.
One dial setting delivers a consistent and safe anesthetic level. Manuals include a "cookbook" protocol which can easily be adapted to your facility's SOP. All waste gases are scavenged for easy evacuation. Breathing circuits allow flat, prone or supine positions with head access. Suitable for mouse, rat, hamster, gerbil, guinea pig, ferret, rabbit, cat, dog or small swine.Positive sealing gasket on induction chambers minimize…
The new Bioscan BioFLECT 400 is the first in vivo optical imaging system offering true 360° fluorescence tomography. BioFLECT uses the photon emission data acquired from 360° and a state-of-the-art 3D reconstruction engine to quantitatively reconstruct the 3D spatial distribution of fluorescent probes in live animals. This approach yields superior, consistent resolution, sensitivity and quantitation throughout the subject. The…
Spectral Instruments Imaging's LAGO offers high throughput imaging for BLI & FLI. With 10 mouse campacity, the LAGO is a fantastic option for high volume imaging cores. This workhorse is designed for non-stop imaging and is the gold standard in sensitiviy - 36% more sensitive than the leading competitor. The LAGO also provides Absolute Calibration, -90C Air Cooled CCD Camera, LED Fluorescence excitation and free software.
BioFLECT™ In Vivo Preclinical Imager - The Only True 360° Tomographic Optical Imager With the launch of the BioFLECT, Bioscan will enable researchers to realize the full potential of in vivo optical imaging for the first time. With BioFLECT’s true 360° tomographic system, researchers will no longer have to choose between imaging only near the surface of the subject or partial tomography solutions that distort the subject or c…
Advanced MRI coil technology delivers highest sensitivity in rat brain in vivo imaging
By far the best available SPECT resolution and sensitivity on the market. Patented 3D focusing capability for dynamic nuclear microscopy in organs and tumors. Ultra-fast imaging with multi-physiologic gating reveals dynamic processes with unprecedented time resolution, ideal for pharmacokinetic imaging.Patented M5™ collimation satisfies widest range of resolution, sensitivity and FOV needs. High reliability and long life due…
The fluorescent dye calcein acetoxymethylester (calcein AM) can be used with Corning FluoroBlok Cell Permeable Supports and Insert Systems to label cells when performing analyses such as tumor cell invasion, endothelial cell migration, endothelial cell tubulogenesis, and other cell-based assays.The cell viability indicator calcein AM is a non-fluorescent, cell permeant compound that is hydrolyzed by intracellular esterases int…
The fluorescent dye calcein acetoxymethylester (calcein AM) can be used with Corning FluoroBlok Cell Permeable Supports and Insert Systems to label cells when performing analyses such as tumor cell invasion, endothelial cell migration, endothelial cell tubulogenesis, and other cell-based assays.The cell viability indicator calcein AM is a non-fluorescent, cell permeant compound that is hydrolyzed by intracellular esterases int…
The fluorescent dyeDiIC12(3) can be used with Corning FluoroBlok Cell Permeable Supports and Insert Systems to label cells when performing analyses such as tumor cell invasion, endothelial cell migration, endothelial cell tubulogenesis, and other cell-based assays.DiIC12(3) is a lipophilic neuronal tracer that is commonly used for labeling neuronal projections as well as lipid bilayers in other cell types. Because DiIC12(3) ex…