Ca++Pure-HA Chromatography Media
Tosoh Bioscience - SeparationsCa++Pure-HA is a hydroxyapatite resin used in the chromatographic separation of biomolecules.
Ca++Pure-HA is a hydroxyapatite resin used in the chromatographic separation of biomolecules.
Empower™ 3 Method Validation Manager (MVM), an option for Empower 3 Chromatography Software, allows you to perform chromatographic method validation, from protocol planning through final reporting, in one application.With Empower 3 MVM you can automatically: Manage method validation workflow in one comprehensive, automated application Clearly display the status of ongoing validation studies – enabling you to see at what…
Cogent Bidentate C8™ HPLC Columns are manufactured with TYPE-C™ silica (silica hydride) and a straight chain C8 hydrocarbon bonded directly to the Silica Hydride surface with two separate points of attachment. The manufacturing of the Silica makes these columns virtually indestructible.
The BLC-30 from Buck Scientific offers analytical versatility at an excellent price. The BLC-30 HPLC is an isocratic system with a variable wavelength detector. The BLC-30 Series Analytical HPLC systems use a high-quality, precision monochromator based spectrophotometer for a full range of wavelengths from 190-800nm for selective analyses integrated into a complete LC package. The 20-series is easily upgraded to a gradient Sy…
We offer the Sanwatsusho degasser with our HPLC line for those who are dealing with samples which are aerated. Specifications: Max flow rate 7ml/min Residual dissolved oxygen: 0.8 ppm maximum at flow rate of 1 ml/min. Pressure Loss - 0.6 kPa - (0.006 kg/cm2 or 0.086 psi) at flow rate of 1 ml/minute Internal Volume : 10ml
Filter Fluorescence Detector For HPLC - Customer to select wavelength. The new DFL-10 HPLC Fluorescence detector provides the sensitivity and the specificity of fluorescence detection at a price consistent with most low cost UV detectors.The DFL-10 can be configured with a choice of lamps covering the UV and Visible regions of the spectrum. Choices include Deuterium (at an additional cost with a recommended expanded range pho…
Fraction Collector - 116 tube capacity for 10 to 16 mm tubes. Our fraction collector can be operated as a simple fraction collector, where each fraction is the same size and the fraction size is set in terms of time, drops, or external events (like counts from a pump). A simple command entered from the membrane keypad enables the internal peak detector. This allows you to collect only those peaks of interest from the chromato…
We have found the Schambeck Refractive Index Detector to work very well with our HPLCs. Our fraction collector can be operated as a simple fraction collector, where each fraction is the same size and the fraction size is set in terms of time, drops, or external events (like counts from a pump). A simple command entered from the membrane keypad enables the internal peak detector. This allows you to collect only those peaks of…
Spark Holland OPTIMAS 84 Position Autosampler. OPTIMAS features our proven PASA injection concept, combining robust injection with high precision and accuracy. With its three injection modes including zero sample loss injection, OPTIMAS rivals top-class autosampler performance, while challenging middle-class autosampler prices! Features: Reliable PASA injection technology Superior price/ performance ratio Sample c…
The use of an ultra pure, ultra inert silica has many recognised benefits, including improved reproducibility, lifetime and chromatographic performance (particularly with basic molecules). However, since the ultra inert silica surface effectively no longer contributes to the separation, C18 columns manufactured with high purity silicas show near identical selectivity. It is therefore highly likely that a problem separation on…
Coated and immobilized CHIRAL ART polysaccharide columns by YMC offer wide selectivity range, high stability and attractive pricing.
The SEDEX Model 75 provides the option of 4 new nebulizers and a redesigned evaporation tube. These changes allow you to use a lower temperature to evaporate the mobile phase, this provides a more uniform droplet size, maximizing the sensitivity and repeatability. Enhanced ease of operation The SEDEX Model 75 is designed to be very easy to use. The operator needs to set only three controls, the gain, the zero and the evaporati…
4.6mm, 4.0mm, 2.0mm, and 1.0mm ID HPLC columns are available in lengths of 50mm, 100mm, 150mm, and 250mm. SGE has biocompatible GLT columns available for applications requiring truly inert HPLC columns. SGE HPLC columns offer brilliant results for reverse phase, and normal phase HPLC applications.
The LC-4000 Series is the latest in a long history of innovative HPLC systems developed by JASCO reaching all the way back to the start of commercial HPLC in the early 1970s. The concept of the integrated LC-4000 series HPLC provides key separation platforms at 50MPa, 70MPa and 130MPa which correspond to conventional HPLC, the increasingly popular Rapid Analysis (RHPLC) and sub 2um UHPLC, respectively. Each platform is suppl…
The LC-4000 Series autosamplers provide a range of options to suit any sample injection requirements, from the AS-4050 entry-level model, to the AS-4250 UHPLC model or the AS-4058 preparative scale autosampler. All LC-4000 series autosamplers share the same simple maintenance features, with consumable parts such as injection ports, rotor seals, and loops accessible from the front panel for easy replacement.
The LC-4000 Series column ovens have been designed to provide excellent utility for a wide range of different user requirements.For simple requirements the stackable CO-4061 can be used with column lengths up to 200mm (or up to 300mm with an optional extension). For RHPLC and UHPLC the CO-4062 has capacity for up to six 150 mm length columns, with optional one or two internally mounted automatic switching valves for 2 or 6 co…
Using the advanced Czerny- Turnermonochromator design with optimization of the optical sys tem, baseline change due to refrac tive index is minimized.Baseline fluctuation from changes in environmental temperature is reduced with a temperature - controlled cell, baseline drift caused by temperature fluctuation in the light source is also reduced with a temperature controlled light source. The result is excellent stability with…
The LC-4000 Series includes three PDA detectors.The MD - 4 017 is a useful replacement for a single wavelength detector, the MD-4015 is the workhor se for UV- visible detection in the range 200 to 600nm and the MD-4010 is designed for high sensitivity and high spectral and time resolution. The MD-4010 PDA detector offers the highest detection sensitivity, equivalent to a single wavelength detec tor. Making use of a 1024 eleme…
The Refractive Index detectors include the optical system mounted in a precisely temperature-regulated housing to eliminate the influence of changes in ambient temperature.The RI-4030 and 4035 detectors are fully stable just one hour after powering on. The RI-4030 can be used for both analytical and preparative scales. In preparative mode the maximum flow rate is 120 ml/min. The RI-4035 is a dedicated semi-micro RI detector wi…
The FP-4020 fluorescence detector has been designed for the pursuit of extreme sensitivity.Re-designing the optics and electronics from the ground up, as well as removing the effects of ambient temperature with a new temperature- regulated cell body has led to the highest sensitivity with stable detection. The new axially irradiated cell design enables the very highest sensitivity detection. These changes have resulted in a gi…
The OR-4090 Chiral detector measures the angle of rotation of plane polarized light caused by optical active isomers and is useful for chiral compounds with no absorption.The OR-4090 uses a high intensity Hg-Xe arc lamp (150W) providing a strong output in the UV/Visible region where the largest optical rotations offer the highest sensitivity. The wide wavelength range from 350-900nm also allows measurement of a wide variety of…
HPLC and UHPLC method compatibility at the flip of a switch.
Visco Mixers are static mixers for HPLC and other high pressure applications. The Lee Visco-Jet Micro-Mixer uses aerospace technology to provide the ultimate in static mixing efficiency. A series of 36 critically controlled spin chambers subject the incoming liquids to a vigorously repeated mixing process. No electrical or mechanical input is required – the mixing energy is drawn from the liquids themselves. Two sizes ar…