Food and Beverage Products & Reviews
3Mâ„¢ Emporeâ„¢ C8-HD 1ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3Mâ„¢ Emporeâ„¢ C8-SD 1ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3Mâ„¢ Emporeâ„¢ C18-SD 1ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3Mâ„¢ Emporeâ„¢ C8-SD 3ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3Mâ„¢ Emporeâ„¢ C18-SD 3ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3Mâ„¢ Emporeâ„¢ UR-SD 3ml Cartridge
3M BioanalyticalThis chemistry promotes high retention of a wide range of analytes, reducing method development time and facilitating a generic approach to sample preparation.
3Mâ„¢ Emporeâ„¢ C18-SD 6ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3Mâ„¢ Emporeâ„¢ SDB-XC 6ml Cartridge
3M BioanalyticalSDB-XC is a poly(styrenedivinylbenzene) copolymer used as a reversed phase sorbent for solid phase extraction. SDB-XC is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked. It does not exhibit the secondary cationic (silanol) interactions and pH limitations common to bonded silica sorbents, so it offers more predictable and reproducible reversed phase interaction.
Emporeâ„¢ Accessory Vacuum Manifold for 96 Well Plates
3M BioanalyticalThe Empore™ High Performance Extraction Disk Plate differs in design from plates offered by other manufacturers and requires a specific vacuum manifold. Manifolds supplied by different plate manufacturers are specific to the design of their plates and cannot generally be used with plates from other manufacturers. In some cases, the use of spacers to raise/lower the height of a collection device inside the manifold may overco…
Emporeâ„¢ Accessory Replacement Gasket for 96 Well Plate vacuum Manifold
3M BioanalyticalReplacement gaskets are available with the vacuum manifold assembly. The gasket can become worn over time and the seal between the plate and the manifold will be affected. This may result in poor vacuum pressure and negatively effect flow rates. The gasket should be checked regularly and replaced when it becomes worn.
Emporeâ„¢ Accessory Filter Aid 400
3M BioanalyticalEmpore Filter Aid 400 has been shown to improve flow rates and recoveries for separation and filtration of water samples containing suspended solids. When placed on top of the Empore™ Extraction Disk at a depth of about 1 cm, Empore™ Filter Aid 400 acts as depth filter to inhibit the migration of suspended solids to the surface of the disk. This reduces extraction time and improves rates and recovery of analytes.
Ascentis® C18 HPLC column, 3micron, 15cm L x 4.6mm ID
Sigma-Aldrich SupelcoThe Ascentis family of columns is the fourth generation of HPLC column technology from Supelco scientists. Ascentis columns are bonded on high purity, 100 Angstrom silica including 3, 5, and 10 micron particle size. Columns are designed for small molecule applications and are scalable from micro columns (1.0 mm I.D.) to preparative dimensions (50 mm I.D.). The family includes C18, C8, Phenyl, Si and embedded polar group phase,…
Analyst® Software
Thermo Fisher ScientificAs the World’s most commonly used LC/MS/MS instrument control software platform with more than 15,000 users worldwide, Analyst® software, which is based on industry leading architecture, provides state of the art functionality for instrument control, data analysis and reporting. The latest version, Analyst Software version 1.5 builds on this legacy by providing new features that both enhance performance as well as ease of use.…
LCQ Fleet Ion Trap MSn
Thermo Fisher ScientificThe LCQ Fleet delivers rich information for routine analysis of complex samples with high-throughput and provides excellent full-scan sensitivity, ruggedness and reliability. From the inventors of benchtop LC/MS ion trap technology, this reliable and easy to use ion trap mass spectrometer offers exceptional analytical value while providing confident sample analysis. The new cost effective LCQ Fleet delivers rich information f…
SeQuant® ZIC®-HILIC HPLC Columns
Merck KGaA, Darmstadt, GermanyZIC®-HILIC HPLC columns for the separation of all classes of polar and hydrophilic compounds. What is HILIC? HILIC or Hydrophilic Interaction Liquid Chromatography is a straightforward chromatographic technique for separation of many types of polar and hydrophilic compounds. To put it simple one can say that HILIC is a normal-phase (NPLC) type of separation but uses reversed-phase (RPLC) type eluents. In HILIC one has: A c…
Power SYBR® Green RNA-to-CT™ 1-Step Kit
Thermo Fisher ScientificThe Power SYBR® Green RNA-to-CT™ 1-Step Kit provides high sensitivity and specificity in an easy-to-use one-step qRT-PCR reaction kit. A novel formulation helps reduce false-positive results caused by primer-dimers that are common in SYBR® Green-based assays. This significantly improves data accuracy and enables the reliable detection of low expressing targets or targets present at low amounts. Minimized hands-on time wit…
Power SYBR® Green RNA-to-CT 2-Step Kit
Thermo Fisher ScientificPower SYBR® Green RNA-to-CT 2-Step Kit is a flexible kit that enables a two-step protocol for performing reverse transcription and cDNA quantitation by real-time PCR. The kit includes the High Capacity RNA-to-cDNA and the PowerSYBR® Green PCR Master Mix. The High Capacity RNA-to-cDNA Kit is used to first reverse transcribe RNA into cDNA and the resulting cDNA is then quantitated using the PowerSYBR® Green PCR Master Mix for…
SYBR® Green RT-PCR Reagents
Thermo Fisher ScientificThe SYBR Green RT-PCR Kit provides all the necessary components to perform both one- and two-step RT-PCR, which makes it ideal for evaluation between the two RT-PCR protocols.
HySphereâ„¢ C8 EC-SE
Spark System Solutions B.V.Spark has introduced the second edition of HySphereâ„¢ C8 End-Capped cartridges. We have selected a new perfect Spherical sorbent material with a narrow particle size distribution. This will create less back pressure during operation and allows you to run higher flow rates compared to our current HySphereâ„¢ C8 (EC). The new cartridge has the same excellent characteristics such as high extraction capacity and selectivity