Environmental Products & Reviews

Product Filter

Field

See more

Technique

Search within technique

Company

Search within company

Ratings

3584 Products found | Selected filters:

Clear Filters
25
Best match
ProductsSeparations

3Mâ„¢ Emporeâ„¢ C8-SD Standard Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

ProductsSeparations

3Mâ„¢ Emporeâ„¢ C18-SD Standard Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

ProductsSeparations

3Mâ„¢ Emporeâ„¢ MPC-SD Standard Well Plate

3M Bioanalytical

This mixed phase chemistry, in which two primary modes of attraction are present, allows for a more efficient and selective extraction compared to traditional reversed phase techniques.  Neutral and ionized analytes can be simultaneously extracted from a complex mixture and eluted as separate fractions.  A mixed phase sorbent offers the following advantages: Eluting acidic and neutral analytes separately from basic analy…

0.0/5.0
|0 Reviews



ProductsSeparations

3Mâ„¢ Emporeâ„¢ C8-SD Deep Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

ProductsSeparations

3Mâ„¢ Emporeâ„¢ C18-SD Deep Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

ProductsSeparations

3Mâ„¢ Emporeâ„¢ MPC-SD Deep Well Plate

3M Bioanalytical

This mixed phase chemistry, in which two primary modes of attraction are present, allows for a more efficient and selective extraction compared to traditional reversed phase techniques.  Neutral and ionized analytes can be simultaneously extracted from a complex mixture and eluted as separate fractions. A mixed phase sorbent offers the following advantages: Eluting acidic and neutral analytes separately from basic analyt…

0.0/5.0
|0 Reviews



ProductsSeparations

Emporeâ„¢ Accessory Vacuum Manifold for 96 Well Plates

3M Bioanalytical

The Empore™ High Performance Extraction Disk Plate differs in design from plates offered by other manufacturers and requires a specific vacuum manifold.  Manifolds supplied by different plate manufacturers are specific to the design of their plates and cannot generally be used with plates from other manufacturers.  In some cases, the use of spacers to raise/lower the height of a collection device inside the manifold may overco…

0.0/5.0
|0 Reviews


ProductsSeparations

Emporeâ„¢ Accessory Sealing Tape Pad for 96 Well Plates

3M Bioanalytical

EmporeTM Tape Pads are intended for sealing unused portions of a 96-well solid phase extraction plate during vacuum processing to enable vacuum to be uniformly applied to each well being used.  Use a clean sheet each time for maximum sealing ability.  Note: these tape sheets are not intended for sealing collection plates prior to sample injection because the adhesive may clog the injection needle.

0.0/5.0
|0 Reviews

ProductsSeparations

Emporeâ„¢ Accessory Filter Aid 400

3M Bioanalytical

Empore Filter Aid 400 has been shown to improve flow rates and recoveries for separation and filtration of water samples containing suspended solids.  When placed on top of the Empore™ Extraction Disk at a depth of about 1 cm, Empore™ Filter Aid 400 acts as depth filter to inhibit the migration of suspended solids to the surface of the disk.  This reduces extraction time and improves rates and recovery of analytes.

0.0/5.0
|0 Reviews

ProductsSeparations

Ascentis® C18 HPLC column, 3micron, 15cm L x 4.6mm ID

Sigma-Aldrich Supelco

The Ascentis family of columns is the fourth generation of HPLC column technology from Supelco scientists. Ascentis columns are bonded on high purity, 100 Angstrom silica including 3, 5, and 10 micron particle size. Columns are designed for small molecule applications and are scalable from micro columns (1.0 mm I.D.) to preparative dimensions (50 mm I.D.). The family includes C18, C8, Phenyl, Si and embedded polar group phase,…

0.0/5.0
|0 Reviews

ProductsSeparations

Analyst® Software

Thermo Fisher Scientific

As the World’s most commonly used LC/MS/MS instrument control software platform with more than 15,000 users worldwide, Analyst® software, which is based on industry leading architecture, provides state of the art functionality for instrument control, data analysis and reporting. The latest version, Analyst Software version 1.5 builds on this legacy by providing new features that both enhance performance as well as ease of use.…

0.0/5.0
|0 Reviews

ProductsSeparations

LCQ Fleet Ion Trap MSn

Thermo Fisher Scientific

The LCQ Fleet delivers rich information for routine analysis of complex samples with high-throughput and provides excellent full-scan sensitivity, ruggedness and reliability. From the inventors of benchtop LC/MS ion trap technology, this reliable and easy to use ion trap mass spectrometer offers exceptional analytical value while providing confident sample analysis. The new cost effective LCQ Fleet delivers rich information f…

0.0/5.0
|0 Reviews

ProductsSeparations

Rocket Synergy Evaporator

Genevac

Rocket Evaporators use patented vacuum technology to evaporate solutions to dryness, or a concentrate, rapidly and safely. The latest Synergy series offers integrated, flexible solutions for processing a wide range of sample volumes. Interchangeable rotors will accommodate tubes, flasks and batch volumes of up to 100L. Rocket Synergy is designed primarily to quickly process larger volumes of solvent in parallel and witho…

0.0/5.0
|0 Reviews

ProductsSeparations

SeQuant® ZIC®-HILIC HPLC Columns

Merck KGaA, Darmstadt, Germany

ZIC®-HILIC HPLC columns for the separation of all classes of polar and hydrophilic compounds. What is HILIC? HILIC or Hydrophilic Interaction Liquid Chromatography is a straightforward chromatographic technique for separation of many types of polar and hydrophilic compounds. To put it simple one can say that HILIC is a normal-phase (NPLC) type of separation but uses reversed-phase (RPLC) type eluents. In HILIC one has: A c…

0.0/5.0
|0 Reviews

ProductsSeparations

Corning® 150 mL Bottle Top Vacuum Filter, 0.45 µm Pore 13.6cm² CA Membrane, Fits 33 mm Diameter Necks, Sterile, 48/Case

Corning Life Sciences

Fits plastic or glass media bottles with 33mm neck sizes. Cellulose acetate (CA) membranes provide fast flow rates and low protein binding and are good for filtering cell culture media. Angled hose connector simplifies vacuum line attachment. Individually packaged, sterile and certified nonpyrogenic. Each system has the membrane material and pore size printed on the unit and is color-coded by membrane type for easy produ…

0.0/5.0
|0 Reviews


ProductsSeparations

Pulsed discharge detectors Model D-2

VICI AG International

VICI introduces the GC detector where the PDD (pulsed discharge detector) utilizes a stable, low-powered, pulsed DC discharge in helium as the ionization source. The D-2 is a dual mode, universal detector system which can be retrofitted to your older GC. The D-2-I is a helium photoionization detector, optimized for trace level work with packed columns. The stand-alone systems include detector, controller, electrometer, helium…

0.0/5.0
|0 Reviews

ProductsSeparations

Pulsed discharge detectors Model D-3

VICI AG International

Pulsed discharge detector Model D-3 is designed for plug-and-play installation on Agilent GC's, with models available for the 6890 and 7890. The D-3 is optimized for trace level work in the helium photoionization mode, and utilizes the electronics and power supply of the host GC. Model D-5 is optimized for electron capture detection. Available for 110 VAC and 230 VAC.

0.0/5.0
|0 Reviews