Products & ReviewSpectroscopy

Agilent 7850 ICP-MS

Agilent TechnologiesAvailable: Worldwide

Free your ICP-MS analysis from common time traps with the Agilent 7850 ICP-MS. It’s the smart way to reduce wasted time so busy staff can focus on tasks that deliver value.? The 7850 ICP-MS instrument can handle samples with up to 25% solids, reducing the dilution time trap. The instrument features a helium mode collision cell and half mass correction that remove both polyatomic and doubly charged ion interferences, making me…

Request Pricing
Agilent Technologies

Receive your quote directly from the manufacturer.

Reviews

Average Rating 4.5

|2Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Service calls are high.

 

Average Rating 4.0

Application Area:

Metal analysis in food sample

We are getting good service but service calls are so high.

Review Date: 19 Nov 2023 | Agilent Technologies

Must have for Prop 65 Compliance

 

Average Rating 5.0

Application Area:

Prop 65 Testing

Instrument is robust, user friendly, easy to PM and maintain. Can run a range of samples, easily interchangeable for any minerals. Absolutely phenomenal instrument. Cannot operate lab without it. Keeps our customers happy knowing their products are Prop 65 compliant.

Review Date: 20 Apr 2023 | Agilent Technologies

Free your ICP-MS analysis from common time traps with the Agilent 7850 ICP-MS. It’s the smart way to reduce wasted time so busy staff can focus on tasks that deliver value.​ The 7850 ICP-MS instrument can handle samples with up to 25% solids, reducing the dilution time trap. The instrument features a helium mode collision cell and half mass correction that remove both polyatomic and doubly charged ion interferences, making method development simpler and addressing a common cause of time-wasting sample remeasurement.

Check out how the Agilent 7850 ICP-MS instrument boosts lab efficiency and helps reclaim wasted time throughout your ICP-MS analysis.

Features:

  • Standard operating procedures and fully developed methods for regulated and routine methods save you weeks of method development and documentation time.
  • Ultra High Matrix Introduction (UHMI) reduces sample preparation time by allowing you to directly analyze samples containing up to 25% total dissolved solids without dilution. ​
  • Helium collision cell and half-mass correction remove troublesome polyatomic and doubly-charged interferences that can reduce data quality and increase the need for costly sample remeasurements.​
  • Measure high matrix samples without having to matrix-match calibration standards. Hydrochloric acid can also be added to stabilize important elements including Hg, Ag, Mo without introducing new interferences.​
  • Identify unusual sample matrices using IntelliQuant and get a complete elemental profile of each sample. A range of displays, including Periodic table heat map allow you to easily identify abnormal levels of major or unexpected elements.​
  • Outlier Conditional Formatting (OCF) reduces data review times for busy or inexperienced ICP-MS operators by highlighting results that are outside a nominated range or have failed a test requirement. Alerts can be configured for different requirements.​
  • Early Maintenance Feedback (EMF) uses sensors and counters to determine when maintenance is needed. Traffic light, color-coded alerts means maintenance tasks are never missed but are also not performed more frequently than necessary.​
  • ICP Go is an optional, browser-based user-interface for mobile devices offering simplified set up and control of routine sample batches and is great for ICP-MS operators on the move.​
  • Method-specific Analyzer packages containing ICP-MS hardware, software, consumables, professional services and documentation ensure you’ll be running samples in weeks, instead of the months it can take to develop, optimize, verify and document a regulated method.​

Brochures

Product brochuresLab Automation

Agilent automation for ICP workflows

Agilent Technologies offers a completely integrated ICP workflow automation system – comprising hardware, software, and support – designed to free up analysts for more productive pursuits. Agilent's simple and reliable single-vendor solution integrates automated calibration, dilution, analysis, and reporting to lower cost-per-sample and turnaround time while improving the quality of results. Explore the features of Agilent's ICP workflow automation system, comprising the ADS 2 Autodilutor, Advanced Valve System, and SPS 4 Autosampler, fully integrated with the ICP-OES and ICP-MS instruments. Learn how the system can increase productivity and improve workflow efficiency in the lab.

Application NoteLab Automation

Capabilities and operation of Agilent's Advanced Dilution System 2

To increase the efficiency of labs equipped with Agilent ICP-OES or ICP-MS instrumentation, Agilent Technologies has developed the Advanced Dilution System 2 (ADS 2) – a fully integrated inline autodilution system designed for routine, high-throughput applications. The ADS 2 can automatically dilute stock standards and samples up to 400 times, making it ideal for the auto-preparation of calibration standards and samples, or dilution of over-range samples. Explore the features, applications, and benefits of AGS 2 that are helping to automate calibration and sample dilution for ICP-OES and ICP-MS technologies.

Solutions for common metals lab stresses

Agilent’s automated sample dilution systems can solve a range of common problems in a metals analysis lab. Discover how the use of an autosampler means analyses can be performed 24/7, how a switching valve doubles sample throughput, and how the autodilutor automates sample dilutions and standard preparation. Explore how these components work seamlessly together, reducing pressure on laboratories with a single-vendor solution that enables the automation of ICP-OES and ICP-MS analyses.


Introducing

Explore Agilent’s new Advanced Dilution System 2 (ADS 2) autodilutor, which creates an intelligent, all-Agilent automation system for ICP-OES and ICP-MS analyses. Discover how you can simplify your laboratory workflow by automating several laborious and error-prone tasks, such as preparing calibration standards, diluting samples before analysis, and preparing reactive dilutions for over-range samples and QC solution failures.

Product Overview

Links

Buy Agilent 7850 ICP-MS Read Reviews