SCION 456-GC
Bruker CAMThe SCION 456-GC provides industry-leading flexibility by supporting 3 injectors and 4 detectors, including the mass spectrometer, providing our users a rapid time-to-benefit advantage.
The SCION 456-GC provides industry-leading flexibility by supporting 3 injectors and 4 detectors, including the mass spectrometer, providing our users a rapid time-to-benefit advantage.
The Clarus® 680 GC is designed for fast-paced, high-volume laboratories that require fast analytical cycle times. It maximizes throughput with the fastest injection-to-injection time of any conventional gas chromatograph. The Clarus 680 GC incorporates many other PerkinElmer innovations that provide unprecedented operational simplicity and outstanding flexibility while removing the barriers to productivity that can arise with…
If you are involved in the analysis of fragrances, aromas, off-odours and other volatile organic compounds you may well wish that you could target trace componants at the low ppb level. You may also want to work with larger samples, than the 10-20 ml samples that conventional headspace analysis permits. The Entech 7150 Concentrator can be used to trap and focus headspace and air samples up to 1 litre in volume and to inject th…
GC Chemiluminescence Detector for Nitro, Nitroso, and Nitrogen containing compounds
PC/Chrom is a complete package that interfaces your GC or HPLC detector to your personal computer or to a corporate network server. PC/Chrom reads the analog output signal from the detector, digitizes the signal, displays the chromatogram, and processes the data according to user specifications to produce a final report that can be printed. All hardware and software is included in the PC/Chrom package, including power supply a…
Labformatics Balanced Scorecard Approach combines the laboratory performance measurement service suite of Labformatics with the powerful CorStrategy Balanced Scorecard engine from CorVu plc. Over 65% of Fortune 500 organisations are thought to use the Balanced Scorecard approach as part of their business performance management activities. Labformatics Balanced Scorecard Approach is the only product specifically designed fo…
The newest member of the PDD family is also the smallest and thriftiest. The miniPDD uses about one fifth (20%) the amount of helium as the D-3 and D-4 versions, giving up only a bit of sensitivity and dynamic range in return. It is approximately one half the size of the D-4, but has nearly the same sensitivity — about 100 ppb for fixed gases. With its reduced size, weight, and helium consumption, it is particularly well sui…
A Revolutionary System Aimed at Performance and Ease of Use The HS-20 Series is the optimal solution for volatile component analysis. Also, its superior performance and user-friendly design support all types of analyses, from research to quality control. Excellent performance • High reproducibility • Low carryover • High-temperature compatibility User-Friendly Design • User-friendly sample tray • Easy maintenanceExcellent Expa…
Bruker’s innovative PIONA+™ Analyzer, based on the powerful 450-GC gas chromatograph, provides a highly flexible platform to obtain comprehensive characterization and quantitative information, including hydrocarbon group types, aromatics and oxygenates per carbon number for spark emission fuels. The system comes complete with ultra high performance columns and traps, CompassCDS™ chromatography data handling software and PIONA+…
ACTI-VOC™ is a robust low-flow pump for sampling vapour-phase organic compounds (VOCs) onto sorbent tubes for subsequent analysis by thermal desorption (TD). Being lightweight, easy-to-use and intrinsically safe, ACTI-VOC is ideal for personal monitoring and a wide range of other air and gas sampling applications. Optimised for thermal desorption tubes Unlike other personal monitoring pumps on the market, ACTI-VOC is optimised…
HT3000A is a liquid GC autosampler that offers reliability and superior performance for all GC-GCMS applications. The HT3000A is the most compact autosampler on the market, with a near-to-zero requirement for bench space, while offering a top-class sample capacity (121 positions for 2ml vials). The sample rack can be removed for sample loading or preparation, or for storage elsewhere.It can be easily installed on all the GC a…
The HT2000H Headspace autosampler is made to meet the needs of static headspace injection for GC analysis. HTA's proven superior headspace technology is based on a high performing gastight syringe. Through a short flow path, it eliminates any source of error, such as vial pressurization, valve switching, loop filling or transfer lines assuring repeatability (RSD up to To obtain the highest sample throughput, the progressive s…
HT3100A is a liquid GC autosampler that offers automation for processing up to 15 unattended samples. It handles the most sophisticated sampling techniques: Multi-phase sampling, Sandwich injection, Priority sampling, Ambient headspace sampling, Nanoliter injection. It can be easily installed on all the GC and GC/MS systems available in the market, because of flexibility and modular configuration. It can be configured to serv…
HT3200A is a liquid GC autosampler, that takes advantage of today’s latest technology to deliver even greater reliability, performance, as well as offering an extraordinary GLP experience. The HT3200A has a top class sample capacity: no other offers so many samples (209 2mL sample vials) with near-to-zero bench space requirements.Key features: Easy to use Support all GCs of your lab Fast injection technology Versatili…
The HT2100H is an inexpensive, simple-to-use, as well as reliable headspace unit. With all the quality and reliability you expect, the HT2100H headspace sampler offers exactly the features you need — at a price to fit your budget.The HT2100H is a quality, cost-effective alternative to manual headspace. While manual sampling techniques are simple and inexpensive, they are also tedious, subject to human error and they are not a…
SLB®-IL111 Capillary GC Column for FAME and Petroleum Applications. World’s first commercial column to rate over 100 on our GC column polarity scale. Selectivity most orthogonal to non-polar and intermediate polar phases, resulting in very unique elution patterns. Maximum temperature of 270 ºC is very impressive for such an extremely polar column. Great choice for separation of polarizable analytes (contain double and/or tripl…
SLB-IL60 Ionic Liquid Capillary GC ColumnApplication: Modified (deactivated) version of SLB-IL59 provides better inertness. Selectivity more polar than PEG/wax phases, resulting in unique elution patterns. Higher maximum temperature than PEG/wax columns (300 ºC compared to 270-280 ºC). Excellent alternative to existing PEG/wax columns. Also a good GCxGC column choice. Launched in 2012.USP Code: NonePhase: Non-bonded; 1,12-Di(t…
SLB-IL59 Ionic Liquid Capillary GC Column• Application: Selectivity more polar than PEG/wax phases, resulting in unique elution patterns. Higher maximum temperature than PEG/wax columns (300 ºC compared to 270-280 ºC). Great choice for analysis of neutral and moderately basic analytes. Launched in 2009.• USP Code: None• Phase: Non-bonded; 1,12-Di(tripropylphosphonium)dodecane bis(trifluoromethylsulfonyl)imide• Temp. Limits: Su…
SLB-5ms Capillary GC Column Application: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, pesticides, PCBs, and herbicides) or anywhere a low bleed non-polar column is required. USP Code: Th…
SUPELCOWAX® 10 Capillary GC Column• Application: This column is based on one of the most widely used polar phases, Carbowax 20M, and is a polar column suitable for analyses of solvents, fatty acid methyl esters (FAMEs), food, flavor and fragrance compounds, alcohols, and aromatics. Additionally, this column is a great choice when a polar general purpose column is required.• USP Code: This column meets USP G16 requirements.• Ph…
SP-2560 Capillary GC Column• Application: This highly polar biscyanopropyl column was specifically designed for detailed separation of geometricpositional (cis/trans) isomers of fatty acid methyl esters (FAMEs). It is extremely effective for FAME isomer applications.• USP Code: This column meets USP G5 requirements.• Phase: Non-bonded; poly(biscyanopropyl siloxane)• Temp. Limits: Subambient to 250 °C (isothermal or programmed
Equity-5 Capillary GC Column• Application: This popular column is designed for general purpose applications where a non-polar column is required. The low phenyl content provides thermal stability compared to 100% poly(dimethyl siloxane) columns.• USP Code: This column meets USP G27 and G36 requirements.• Phase: Bonded; poly(5% diphenyl/95% dimethyl siloxane)• Temp. Limits: ≤0.32 mm I.D., • Temp. Limits: ≤0.32 mm I.D., ≥2 μm: -…