Environmental Contaminant Standards
Cambridge Isotope LaboratoriesStandards for Environmental, Food, Water, and Exposure Analysis
Standards for Environmental, Food, Water, and Exposure Analysis
Automated, fast and accurate NIT analysis for whole grain. It offers standard calibrations for protein, oil, starch and moisture determinations in diverse whole grain including wheat, barley, corn, soybean, canola, rice, oats, rye and triticale.
The SA 9000 series is based on the well-proven flow analysis technique. This principle allows even the most complex analysis to be automated reliably on-line, with excellent correlation with laboratory results. This model measures the process stream continuously for 1 or 2 parameters simultaneously.
Meter measures Dissolved Oxygen (DO) to determine water quality in a variety of applications including wastewater, aquariums and fish hatcheries. Simultaneously displays DO and temperature readings.Features automatic temperature compensation and calibration to air. Unit holds and recalls minimum and maximum readings. Comes ready to use in a soft carrying case with belt loop, two spare probe heads, electrolyte and 4 AAA batteri…
AstraGuard uses advanced CCD array, fibre optic coupled spectroscopy to continuously monitor organic levels in the treatment of drinking, process and waste water. The UV absorbance of water at 254nm is a reliable indicator of its aromatic organic carbon content; many studies have proven a correlation with the traditional laboratory tests like TOC, BOD, COD and DOC. The ease of implementing UV254 as a continuous monitoring syst…
GDX600 is designed for gas dosing from 0.35 nanoLiters/minute - suitable for aggressive, toxic and combustible gases. In combination with a MFC calibration gases can be prepared from pure gases or gas mixtures down to the ppb range.
GMS500 for preparation of calibration gases - is a PC controlled gas blending system with thermal mass flow controllers - designed for the use of aggressive, toxic and combustibel gases.
GMS500 for preparation of calibration gases - is a low-cost - PC controlled gas blending system with thermal mass flow controllers - not suitable for aggressive gases.
The FIAstar™ 5000 System is used for the automatic wet chemical analysis of nutrients and other parameters in water, soil and wine, as well as in meat or other food products. Single or multiple parameters can be analysed sequentially using just one Analyser module and Plug & Analyse Method Cassettes. The modular system can be expanded for the simultaneous determination of up to three parameters.The Plug & Analyse concept ensur…
Easily analyze your wide-range carbon and sulfur content with our CS844 for the determination of carbon and sulfur in primary steels, ores, finished metals, ceramics, and other inorganic materials using the combustion technique. State-of-the-art hardware and our exclusive Cornerstone® touch-screen software platform provide your laboratory with increased usability and a lower cost-per-analysis. Additional features — such as…
The Spectroquant® analysis system includes photometers with cell tests and reagent tests which can be identified by barcodes pre-diluted standard solutions in various concentrations for increased reliability requirements residue-free cleaning agents Three-stage concept for internal controls Photometer Check - AQA 1 Easy to perform with certified color standards and/or Certipur® UV/VIS standards. System Check - AQA 2 R…
The Thermo Scientific Developmental Neurotoxicity Panel is the only proven method for analyzing the effect of industrial chemicals on neuronal morphological chemicals in food, consumer products and the environment. The widespread use of these chemicals has led to fears of a link between exposure to such chemicals and the increased incidence of neurological disorders in children. The assay uses Neuroscreen (NS-1) cells, a subcl…
Environmental Monitoring Software Program Environmental Monitoring Program is an application capable of capturing all environmental data in a 21 CFR Part 11 Compliant, fully validated system. It is envisioned for sterile and non sterile health care industries (Pharmaceuticals, Biotech, Chemical, microbiological) food and any other sterile environment based on the latest guidelines from, FDA, EU, ISO 14644-1 and PDA Technical…
The 8000M Mixer/Mill® is a high-energy ball mill that accommodates sample sizes ranging from 0.2 - 10 grams. Ideal for grinding dry, brittle samples. Grinding and mixing vials are available in: hardened steel, stainless steel, tungsten carbide, alumina ceramic, zirconia ceramic, silicon nitride, agate, polystyrene, methacrylate, and polycarbonate. Applications include: Mechanical alloying, slurry grinding, blending powd…
The CAI 600P & 600F digital analyzer is designed around a state-of-the-art 16-bit microprocessor, c an be manually or remotely operated, has precision measurements and more. The California Analytical Models 600P & 600F digital analyzer product line is designed around a state of the art 16 bit microprocessor, with 16 digital inputs, 16 digital outputs, 16 analog inputs and 4 analog outputs. The analyzer can be manually operate…
FTIR Spectroscopy is an analytical technique which measures the infrared intensity versus wavelength (wave number) of light. The FTIR Spectrometer obtains infrared spectra by collecting an interferogram of a sample signal with an interferometer. FTIR Analyzer(s) Highlights: No Liquid Nitrogen Required Compact, Industrial Design w/Fast Repsonse Proven Rugged Interferometer with Gold Mirrors Heated Standard Stainless St…
In Photoacoustic Spectroscopy (PAS) the gas to be measured is irradiated by modulated light of a pre-selected wavelength. The gas molecules absorb some of the light energy and convert it into an acoustic signal which is detected by a microphone. Photoacoustic IR Analyzer(s) Highlights: Low Sensitivity (From ppb to Percent Levels) Yearly Calibration Minimal Maintenance Measures up to Five Gases + H2O Temperature and…
The CAI NOxBox system has been specifically designed for harsh environment condition s frequently found in outdoor selective catalytic reactor applications. The analyzer system is housed in a Nema 4 enclosure with a front lockable door. The enclosure contains a heating and cooling system to maintain a constant internal temperature for the gas analyzer and interface equipment regardless of outside environmental effects. The sa…
The CAI Mark 3 Intelligent Sampling System is a third generation single board computer controlled industrial sequencer. The system has been developed over many years as higher specifications components have been added to the proven single board computers on the Mark 1 and Mark 2 Samplers. These have been in production for over 15 years. CAI specialize in custom building these systems and are able to modify and write special s…
This competitively-priced, single-channel dissolved oxygen meter is easy to set up and use while providing reliable, accurate DO measurement for water analysis and general laboratory applications. The rugged meter displays DO concentration or percent DO Saturation and offers a full complement of GLP-related features. It offers enhanced stability indicators, salinity correction and automatic barometric pressure compensation—…
This waterproof, battery-operated DO meter stands up to the most demanding water analysis applications and delivers over 2,000 hours of continuous operation. Convenient Quick-Start Guide is located on the back of the meter to make the unit easy to operate in the field. The rugged meter displays DO concentration or percent DO Saturation and offers a full complement of GLP-related features. It offers enhanced stability indica…
This waterproof, battery-operated pH/DO meter stands up to the most demanding water analysis applications and delivers over 2,000 hours of continuous operation. Convenient Quick-Start Guide is located on the back of the meter to make the unit easy to operate in the field. The rugged meter displays DO concentration or percent DO Saturation and offers a full complement of GLP-related features—including available 21 CFR Part 11…
Biochemical oxygen demand (BOD) determination is still one of the most important parameters in water resource management. It can be used to evaluate the impact of biodegradable substances in waters and waster water. With its OxiTop ® systems, WTW offers a unique, modular and mercury-free instrument system. It is not only suitable for BOD determination, but also for measuring biodegradability and deple-tion.The advantages of Ox…
Complete packages for 6 or 12 simultaneous measurementsMeasurement using OxiTop ® is based on pressure measurement in a closed system: microorganisms in the sample consume the oxy-gen and form CO 2 . This is absorbed by NaOH, creating a vacuum which can be read directly as a measured value in mg/l BOD.The used sample volume regulates the amount of oxygen available for a complete BOD. Measurement ranges of up to 4,000 mg/l can…