Stericapâ„¢ PLUS Universal Bottle-Top Filter Device
MerckThe Stericap â„¢ PLUS Universal Bottle-Top Filter Device provides fast, large-volume filtration into any sized bottle.
The Stericap â„¢ PLUS Universal Bottle-Top Filter Device provides fast, large-volume filtration into any sized bottle.
• Concentrating and desaltingchromatography column eluates• Concentrating monoclonal antibodies• Concentrating proteins or viruses from culture supernatants• Clarifying tissue homogenates and cell lysates• Buffer exchange or diafiltration
• High recovery Ultracel regenerated cellulose membrane in a range of molecular weight cut-offs• High retentate recovery of >90%• Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes)• Heat-sealed membrane minimizes downstream extractables• 100% integrity tested for reliable performance• Convenient sample monitoring with translucent housing and volume gradations• Direct pipet…
• High recovery Ultracel regenerated cellulose membrane in a range of molecular weight cut-offs• High retentate recovery of >90%• Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 5 minutes)• Heat-sealed membrane minimizes downstream extractables• 100% integrity tested for reliable performance• Convenient sample monitoring with translucent housing and volume gradations• Direct pipette s…
Easy, pre-sterilized, centrifugal sample clarification units for either 0.5 mL (MC) or 2 mL (CL) maximum volumes.High recovery Durapore (PVDF) membraneFast filtration and highly reproducible performanceUse in fixed-angle rotors for 1.5 mL tubes (MC) or 15 mL tubes (CL)
Montage Antibody Purification Kits are designed for fast and easy antibody purification from serum, ascites or cell culture supernatants. The kits include spin columns pre-packed with high capacity PROSEP-A or G media. There are no pumps to setup. No columns to pack. All you need is a centrifuge to purify 10–20 mg in less than 60 minutes.The protocol is easy to follow and, unlike traditional gravity flow methods, the use of ce…
With their vertical membrane design, Amicon Ultra 0.5 mL filters deliver great performance and lower spin timesConcentrates 500 µL down to 15 µLConcentration factor 25 x to 30 xHigh sample recovery (greater than 90% of dilute starting solution)Fast processing time - 10 to 30 minutesConsistent recoveries thanks to the reverse spin capabilityReverse spin capability provides consistent recoveries
With their vertical membrane design, Amicon Ultra 2 mL filters deliver the highest recovery with shortest spin times• Concentrates 2 mL down to 15-70 µl• 98% sample recovery• Fast processing time - 10 to 30 minute spin times• Engineered dead stop• Reverse spin capability provides consistent recoveries
Concentrates 2 mL down to 15-70 µL 98% sample recovery Fast processing time - 10 to 30 minute spin times Engineered dead stop Reverse spin capability provides consistent recoveries
Automation compatible filter units from EMD Millipore are specially designed to provide efficient filtration for dissolution and other automated sample preparation applications.Choice of Filter Media: Automation compatible filter units are available in a variety of membrane types and pore sizes, including units with prefilters for particulate-laden samples.Automation Compatible Packaging: The 200 pack comes preassembled in 8 t…
Millex filter units with hydrophobic Fluoropore membrane are ideal for sterilizing gases, venting sterile containers, and sterilizing or clarifying organic solutions. Specialized filter units protect hemodialysis transducers from blood and moisture. 50 mm Millex filter units are also used for vacuum line protection. All units are bi-directional
This 13 mm syringe filter with a Hydrophilic Polyethersulfone membrane, for non-sterile filtration, has a 0.45 micron pore size used in preparation of aqueous & mild organic solutions prior to chromatography or other instrument analyses.
4 mm syringe filter with a Hydrophilic PVDF membrane, for non-sterile filtration, has a 0.22 µm pore size used in fine particle removal from aqueous & mild organic solutions.
Millex-GP Filter for Samplicity G2, 0.22 µm, PES 33 mm, non-sterile
Bløk Noise Cancelling Reagents are designed especially for Western blotting applications. This family of protein-free, ready-to-use buffers has been optimized to reduce background levels when using chemiluminescence, fluorescent, or phosphotyrosine detection. Bløk buffers are ideal for use with Immobilon®-P Western blotting membranes and the SNAP i.d.® system, and are also compatible with standard Western blotting techniques.
The Luminata ELISA HRP chemiluminescent substrates provide three major advantages:High sensitivity for detecting as little as 0.1 pg of proteinBroad dynamic detection range (up to 2,500-fold), enabling a wide range of quantitation.Flexibility to adjust ELISA signal strength
The MILLIPLEX®MAP Human Soluble Cytokine Receptor - Premixed 14 Plex is used for the simultaneous quantification of the following Human analytes: sCD30 (sTNFRSF8), sgp130, sIL-1RI (sCD121a), sIL-1RII (sCD121b), sIL-2Rα (sCD25), sIL-4R (sCD124), sIL-6R (sCD126), sRAGE, sTNFRI (sTNFRSF1A), sTNFRII (sTNFRSF1B), sVEGFR1 (sFlt-1), sVEGFR2 (sFlk-1), sVEGFR3 (sFlt-4), sEGFR
The MILLIPLEX® MAP Human Cytokine/Chemokine Magnetic Bead Panel II - Premixed 23 Plex is used for the simultaneous quantification of the following Human analytes: 6Ckine, BCA-1, CTACK, ENA-78, Eotaxin-2, Eotaxin-3, I-309, IL-16, IL-20, IL-21, IL-23, IL-28a, IL-33, LIF, MCP-2, MCP-4, MIP-1d, SCF, SDF-1A+β, TARC, TPO, TRAIL, TSLP
The MILLIPLEX® MAP Human Cytokine/Chemokine Magnetic Bead Panel III - Premixed 11 Plexis used for the simultaneous quantification of the following Human analytes: GCP2, HCC-1, I-TAC, IL-11, IL-29, Lymphotactin, M-CSF, MIG, MIP-3α, MIP-3β, NAP2
The MILLIPLEX® MAP Human Cytokine/Chemokine Magnetic Bead Panel III - Premixed 9 Plex is used for the simultaneous quantification of the following Human analytes: GCP2, I-TAC, IL-11, IL-29, Lymphotactin, M-CSF, MIG, MIP-3α, MIP-3β
The MILLIPLEX® MAP Human Cytokine/Chemokine Magnetic Bead Panel II is used for the simultaneous quantification of the following Human analytes: 6Ckine, BCA-1, CTACK, ENA-78, Eotaxin-2, Eotaxin-3, I-309, IL-16, IL-20, IL-21, IL-23, IL-28a, IL-33, LIF, MCP-2, MCP-4, MIP-1d, SCF, SDF-1A+β, TARC, TPO, TRAIL, TSLP
The MILLIPLEX® MAP Human Cytokine/Chemokine Magnetic Bead Panel III is used for the simultaneous quantification of the following Human analytes: GCP2, HCC-1, I-TAC, IL-11, IL-29, Lymphotactin, M-CSF, MIG, MIP-3α, MIP-3β, NAP2
The MILLIPLEX® MAP Human Cytokine/Chemokine Magnetic Bead Panel - Premixed 29 Plex is used for the simultaneous quantification of the following Human analytes: EGF, Eotaxin, G-CSF, GM-CSF, IFN-α2, IFN-γ, IL-10, IL-12 (p40), IL-12 (p70), IL-13, IL-15, IL-17, IL-1ra, IL-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IP-10, MCP-1, MIP-1α, MIP-1β, TNF-α, TNF-β, VEGF