Adept HPLC System 2S
Cecil Instruments LimitedHigh pressure mixing isocratic system, with UV/Visible WaveQuest detector and PowerStream software.
High pressure mixing isocratic system, with UV/Visible WaveQuest detector and PowerStream software.
High pressure mixing isocratic autosampler system, with UV/Visible detector and PowerStream software
High pressure mixing isocratic autosampler system, with WaveQuest detector and PowerStream software.
High pressure mixing binary gradient system, with UV/Visible detector and PowerStream software.
High pressure mixing binary gradient system, with WaveQuest detector and PowerStream software.
Modular high pressure mixing, binary gradient autosampler system
Modular high pressure mixing binary gradient autosampler system
Modular manual isocratic system, with refractive index detection
Specac’s Gateway™ ATR Accessory Kit is an economical multi-reflection horizontal ZnSe ATR accessory. With high-performance transfer optics and anti-reflection coated ZnSe crystals as standard, high optical throughput is achieved to facilitate an excellent standard of FTIR ATR spectral data. The Gateway™ ATR Accessory Kit consists of: an optical unit; a trough top-plate with a 45° angle ZnSe crystal; a flat top-plate with a…
THE PERFECT SOLUTION FOR RADIO HPLC IN QUALITY CONTROL Â
Capable of fast data measurement with sensitivity five times higher than previous models, the GCMS-QP2010 Ultra offers improved applicability for comprehensive two-dimensional GC and ultra-high separation. Shimadzu used new, patented mass spectrometry technology called Advanced Scanning Speed Protocol (ASSP™), a firmware protocol that optimizes the ion transmission hardware parameters with a highly efficient data collection al…
The Specac Mini-Film Maker is designed to produce high-quality thin films of polymer and plastic materials for infrared transmission analysis. This product enables quick and easy hot pressing of samples at any temperature between ambient to 250°C, to give constant and reproducible thickness films over the range 50 to 500 microns with a formed diameter of 15mm. The Mini-Film Maker Kit includes the Mini-Film Maker Press with…
SeqSolve™ is an advanced and user-friendly software solution for the tertiary analysis of Next Generation Sequencing (NGS) data. By integrating state-of-the-art bioinformatics methods into one-click analysis workflows, SeqSolve is the only software able to provide scientists with such a combination of both cutting edge and intuitive user experience. Its Click And Go® technology enables the automatic processing of the data, whi…
The Scicloneâ„¢ G3 NGSx workstation is a complete benchtop solution for the automated construction of up to or greater than 96 libraries per day. For Research Use Only. Not for use in diagnostic procedures.
5 mL capacity with round bottom Self-standing design Black graduations and larger marking spots for easier filling and sample identification Manufactured from polypropylene to withstand temperatures to -196°C Silicone washer for a secure seal Vials may be color coded with inserts (see Cat. No. 430499) Special base design allows vials to be locked into cryogenic rack and tray (Cat. No. 430525 or 431131) for single-hande…
The Specac flagship Autotouch Press is designed for high volume laboratory sample preparation for XRF and other elemental analysis techniques, capable of pressing a single sample in under two minutes when augmented with the Apex automated die system.
Specac’s High Temperature High Pressure Cell (HTHP) Accessory is a multipurpose cell for the FTIR analysis of solid samples in transmission, decomposition, or specular reflectance modes. Sample temperatures up to 800ºC can be obtained and the cell can operate at pressures from vacuum (0.1 torr) to 1000 psi for in-situ reaction studies. The standard HTHP Cell (GS05850) can be used for transmission analysis of 13 mm diameter…
Specac’s Omni Cell System presents a novel approach for the analysis of liquid, mulls, pastes, and cast film samples in UV, Vis, NIR, and IR transmission spectroscopy, with one cell mount being suitable for all applications.
An arrayed or non-arrayed BAC library is the preferred choice for downstream applications such as hybridization screening; full-genome sequencing; BAC end sequencing or physical mapping projects. Amount of clones received is based on a guaranteed coverage and 120Kb average insert size. HMW DNA isolation and QC by HMW DNA enzymatic digestion are included. Deliverables for ARRAYED BAC library: Clones will be arrayed and amplifie…
A pooled BAC library is an invaluable tool for PCR-screening. It allows for the easy retrieval of BAC clones of interest. This type of library is especially useful when genome size is large and creating an arrayed library is cost-prohibitive. We typically construct a minimum 5X BAC library and BAC clones are then pooled and distributed in 96-well plates. Each well will contain about 400-500 original BAC clones. HMW DNA isolati…
Our cDNA libraries feature full-length-enriched and high quality size-fractionated cDNA. cDNA library construction is usually done in slightly-modified versions of pBluescript or pcDNA3.1. Insert sizes will range from about 0.5Kb to 4Kb. Concerning QC steps, we evaluate the average insert size, empty clone rate and clone concentration/tube before shipping out. We always provide a gel picture of randomly selected clones showing…
ASH is APA-based, full-length-enriched, single-stranded cDNA subtraction hybridization library. - ASH cDNA subtraction is full-length-enriched and independent of PCR suppression. - ASH cloning is directional and does not involve normalization. - ASH method provides non-exponential amplification before subtraction because double-stranded cDNA is not required. - ASH method has a better subtraction effect because 1) a high ratio…
Fosmid clones are similar in size (ca. 40kb) to cosmids, but, like BAC clones, they contain replicons derived from the F factor for DNA replication and segregation. Because of this property, they are present in low copy number and consequently more stable than cosmids. Also, the copy control vector can be used for easy DNA purification from fosmid clones. Fosmid libraries are commonly used for closing gaps in a whole genome se…
RealTime ready Custom RT-qPCR Assays and Panels Get a head start on your gene expression analysis with function tested assays for all annotated human, mouse, and rat genes Achieve high specificity using intron-spanning assays based on short hydrolysis LNA-substituted Universal ProbeLibrary (UPL) Probes. Rely on stringently RT-qPCR-tested assays that are compliant with MIQE (Minimum Information for Publication of Quantitati…
Discover More, Sequence Less Built upon the NimbleGen Sequence Capture empirically optimized probe design algorithm with high efficiency uniformity of capture1, and now with expanded coverage of coding exons, SeqCap EZ Exome v3.0 offers increased performance. Capture the most comprehensive picture of the human exome with SeqCap EZ Exome Library v3.0. Based on the latest database builds and offering a 64Mb sequence capture, Seq…