Protein-Pak Hi Res Ion-Exchange
WatersHigh Resolution 5 µm particle for Anion-exchange SAX) HPLC of nucleic acids
High Resolution 5 µm particle for Anion-exchange SAX) HPLC of nucleic acids
Rapid, automatable, and robust protein digestion workflow.
Lot certified oligonucleotide standards that allow you to benchmark column and LC system performance with confidence.
Reversed-Phase nano columns for proteomics
High efficincy low adsorption hardware for aggregate analysis of Adeno Associated virus (AAVs) and small to medium nucleic acids.
High Resolution 2.5 µm particles for Anion-exchange (WAX) HPLC of nucleic acids
IEX, SEC, RP, and HIC columns for Proteins and Peptides
Anion-exchangers (AXC) bonded to a pH stable (i.e., pH 2 -12), methacrylic ester-based polymeric resin for separation of nucelic acids.
High resolution XBridge Oligonucleotide BEH C18 OBD Prep Column, 130Å, 2.5 µm for purfication of oligo nucleotides.
Atlantis Premier BEH Z-HILIC Columns provide an increase in polar analyte retention and offer a different selectivity when compared to other HILIC chemistries, both powerful attributes when performing HILIC methods development. Built using rugged ethylene bridged hybrid particles, these columns are pH stable from pH 2-10; the MaxPeak High Performance Surface hardware technology significantly reduces unwanted analyte/surface i…
Size-based separations of peptides. proteins, and viral vectors
Size-based separations of peptides, proteins, and viral vectors
Reversed-phase based separations of peptides
The Atlantis® T3 HPLC columns set the standard for retention and separation of polar compounds via reversed-phase HPLC. Atlantis® T3 columns are a universal, silica-based, reversed-phase C18 line of HPLC columns that not only retain and separate small, water-soluble polar organic compounds, but also provide superior performance across a wider pH range. Atlantis® columns are the culmination of over 30 years of bonded phase rese…
The ChromaLynx™ Application Manager automates the processing of LC/MS or GC/MS and LC/MS/MS or GC/MS/MS data. While the high chromatographic separation efficiency and narrow peak widths typical of GC/MS often increase the challenge to identify co-eluting components, ChromaLynx facilitates the rapid detection, identification and semi-quantitative determination of all components. Manually reviewing complex chromatograms to locat…
Market Leading LC-TOF-MS with Unrivalled Sensitivity, Exact Mass and Dynamic Range for Qualitative Applications The Waters LCT Premier™ XE is the market-leading orthogonal acceleration time-of-flight (oa-TOF) benchtop mass spectrometer for LC applications. Based on proven and reliable technology, the LCT Premier XE provides unrivalled all round performance for those challenging LC/MS applications. The LCT Premier XE's high sen…
Achieve faster run times and improved sensitivity with a smaller particle size
SunFire™ columns feature excellent low pH stability and improved column lifetime compared to many silica-based HPLC column brands. SunFire columns are packed with state-of-the-art silica and new proprietary C18 and C8 bonding and endcapping for high efficiency, resulting in greater sensitivity. SunFire columns are manufactured to achieve the highest level of chromatographic consistency column-to-column and batch-to-batch. MS-…
Excellent low pH stability and high mass loading capability
ACQUITY UPLC® BEH C18 and C8 columns were designed to be the universal columns of choice for most UPLC® separations by providing the widest pH range.They incorporate trifunctional ligand bonding chemistries which produce superior low pH stability and ultra-low column bleed. This low pH stability is combined with the high pH stability of the 1.7 µm BEH particle to deliver the widest usable pH operating range. In addition, these…
ACQUITY UPLC® BEH Shield RP18 columns combine Waters patented Shield Technology* with BEH Technology™ by incorporating an embedded carbamate group into the bonded phase ligand.Waters shield ligands consistently demonstrate increased retention of phenolic compounds versus straight chain alkyl columns. The alternate selectivity and excellent peak shape from the embedded polar group ligand, when combined with the wide pH range an…
ACQUITY UPLC® BEH Phenyl columns utilize a trifunctional C6 alkyl tether between the phenyl ring and the silyl functionality. This ligand, combined with the same proprietary endcapping processes as the ACQUITY UPLC™ BEH C18 and C8 columns, provides ultra-low column bleed, long column lifetimes and excellent peak shape. This unique combination of ligand and endcap on the 1.7 μm BEH particle creates a new dimension in selectivi…
ACQUITY UPLC® BEH HILIC columns contain the rugged 1.7 μm unbonded BEH particles and are designed to retain and separate very polar basic compounds.These unique columns are optimized and tested to produce efficient and reproducible separations under UPLC® HILIC conditions. ACQUITY UPLC BEH HILIC columns overcome a major weakness of HILIC stationary phases: chemical stability. The unbonded silica stationary phases often used in…