Axoclamp 900A computer-controlled current & voltage clamp

AutoMate Scientific Inc.

Computer-controlled microelectrode current-clamp and voltage-clamp amplifier, useful for a wide range of intracellular microelectrode recording techniques with several modes of operation: two independent current clamp amplifiers with bridge balance, two-electrode voltage clamp, discontinuous current clamp, discontinuous single-electrode voltage clamp, and high-voltage current clamp. Axoclamp 900A is shipped with the following…

0.0/5.0
|0 Reviews

Axopatch 200B-2 capacitor feedback patch clamp amplifier

AutoMate Scientific Inc.

Premier patch-clamp amplifier for all patch-clamp configurations, with capacitive-feedback and cooling in the headstage for ultra-low noise single-channel recordings. Axopatch 200B is shipped with the following,o Axopatch 200B amplifiero CV-203BU headstage (Part number 1-CV 203BU)o US Power cord (Part number 1-3010-0011)o European power cord, CEE7/7 (Part number 1-3010-0013)o Accessory kit (Part number1-2050-0301) containing:…

0.0/5.0
|0 Reviews

Delta T Starter Kit - Heated Dish Stage

AutoMate Scientific Inc.

Finally, a culture dish system specifically designed for live-cell microscopy! Now you can have accurate temperature control and high numeric aperture compatibility in a convenient disposable culture dish system compatible with all modes of microscopy. Never before has there been so many capabilities integrated into a specimen control system. • Easily adapted to a variety of specimen types from monolayered adherent cells to t…

0.0/5.0
|0 Reviews

FCS2 Starter Set: FCS2 Chamber, Chamber Controller, 5 Microaqueduct Slides, 50-40mm Coverslips, and Gasket Set (30/set)

AutoMate Scientific Inc.

Chamber, Controller, 5 Microaqueduct slides, 30 piece gasket set, 50 - #1.5 coverslips. The Objective Heater and Objective Heater Controller is optional (needed for use of high numeric aperture objectives). The objective heater is mounted to the upper end of the central retracting tube of the objective. The standard size fits diameters between 17 and 28mm. The medium size fits diameters between 23 and 29mm. There is also a la…

0.0/5.0
|0 Reviews

Glass Culture Cylinder Starter Set (2, 4, 6, 8, 10 mm i.d x 5mm high)

AutoMate Scientific Inc.

Culturing Cylinders are used to barricade cells or suspended specimens in a Delta T® Culture Dish or to restrict and concentrate the growth and location of cells plated on an FCS2® Coverslip. They are 5mm high and available in a variety of inside diameters including 1mm, 2mm, 4mm, 6mm, 8mm, 10mm, and 12mm. The outer diameter is always 2mm greater than the inside diameter due to the 1mm wall thickness. The cylinders are made of…

0.0/5.0
|0 Reviews

Objective Heater Controller

AutoMate Scientific Inc.

To eliminate the heat loss from the specimen, Bioptechs developed a patented Objective Heater System®, which includes a heater/sensor and an electronic controller specifically designed for this purpose. The heater/sensor is comprised of an adjustable thin-film heating band which surrounds 3/4 of the diameter of the upper region of the central retracting tube of the objective. A temperature probe positioned in the gap formed be…

0.0/5.0
|0 Reviews

FCS3 Starter Set: FCS3 Chamber, Chamber Controller, 5 Microaqueduct Slides, 50- #1.5,40mm Coverslips, and Gasket Set (30/set)

AutoMate Scientific Inc.

A closed system, parallel plate, micro-environmental chamber for upright microscopes. The FCS3 provides the user with all of the functionality of the popular FCS2 but redesigned for upright microscopes. Therefore, you have the following attributes in one easy to load and use chamber:•Suitable for no flow through high rate flow procedures where a rapid exchange of media is required with low cell surface shear•Cell temperature c…

0.0/5.0
|0 Reviews

Constant Voltage Stimulator

AutoMate Scientific Inc.

Brief pulses of electricity are used in various biomedical research applications as a stimulus to excite nerve or muscle fibers. Several factors need to be considered when choosing the right stimulator.The DS2A Mk.II provides a precise Constant Voltage stimulus (up to 100V) controllable in Pulse Duration and Amplitude from self-contained batteries, making it ideally suited to electrophysiological recording in small preparation…

0.0/5.0
|0 Reviews

Constant Current Stimulator

AutoMate Scientific Inc.

Brief pulses of electricity are used in various biomedical research applications as a stimulus to excite nerve or muscle fibers. Several factors need to be considered when choosing the right stimulator.The DS3 provides a precise Constant Current stimulus (up to 32mA) controllable in Pulse Duration and Amplitude and as with the DS2A this output comes from self-contained batteries. The DS3 also features a "clamp" or discharge c…

0.0/5.0
|0 Reviews

Bi-phasic Stimulus Isolator

AutoMate Scientific Inc.

The DS4 takes an analogue voltage waveform defined within your own data acquisition/ control system and converts it into an isolated constant current stimulus. The DS4 will accept several input voltage ranges and produces four output ranges (±10µA, ±100µA, ±1mA and ±10mA). It also features a GATE input, so that several DS4 units can be controlled by a single analog waveform, but enabled individually via this GATE input. A t…

0.0/5.0
|0 Reviews

ProductsGeneral Lab

Equipment Rack 63

AutoMate Scientific Inc.

• Standard 19” panel width (21.34” overall)• Usable depth of 16.5" without doors, 16" with doors (17.5" overall)• Knockdown rack unit is shipped in a flat pack container for handling ease & protection (see below)• Perfect for tight access areas or 1 person installations as unit is knocked down into 5 easy to handle parts (ie...2 sides, top, bottom and 4 panel rails) • Complete with; 4 infinitely adjustable - combination rack m…

0.0/5.0
|0 Reviews

µ-Slide I - ibiTreat, tissue culture treated, sterile

AutoMate Scientific Inc.

Combination of a cell culture dish and a cover slip for imaging inside a channel• 100µl channel – small volume• suited for immunofluorescence • real time imaging during staining process• available with elastic surface• large observation area for microscopy• high resolution microscopy of living and fixed cells• lids for long term cultivationrecommended volume per reservoir600 µlnumber of channels1volume of the channel100 µlheig…

0.0/5.0
|0 Reviews

µ-Dish 35mm, low, ibiTreat, tissue culture treated, sterile

AutoMate Scientific Inc.

35mm Petri dish with a thin bottom for high end microscopy – with low walls• ideal cell growth with ibiTreat surface• low walls > cell manipulation combined with high resolution microscopy• lid with lock position for minimized evaporation• perfect cell imaging with fluorescence microscopy and phase contrast• no glue > no cell harm• 3 lid positions adjustable• suitable for DIC (without lid)Ø µ-Dish 35mm, low35 mmrecommended vol…

0.0/5.0
|0 Reviews

µ-Slide Chemotaxis - ibiTreat, tissue culture treated,

AutoMate Scientific Inc.

µ-Slide for stable gradients, 3 chambers on one slide for chemotaxis and migration assays• long term chemotaxis experiments with adherent cells• ready to use system, no assembling• linear gradients, stable for over 48 hours• 3 chambers on one slide for parallel working• adapters for different pipettes• made for high-end video microscopybasic principle: two large reservoirs of 40µl are connected by a narrow observation areathe…

0.0/5.0
|0 Reviews

µ-Slide Angiogenesis, ibiTreat, tissue culture treated, sterile

AutoMate Scientific Inc.

µ-Slide for cell microscopy on or in 3D-gel matrices, providing flat gel surfaces with a minimum of gel used• flat gel surface > all cells in focus• homogeneous 0.8mm thick gel layer• 4 mm well in 5 mm well• use only 10 µl of gel per well+• low evaporation• compatible with multi channel pipettesnumber of wells15volume inner well10 µlØ inner well4 mmvolume upper well50 µlØ upper well5 mmgrowth area per inner well0.125 cm2bottom…

0.0/5.0
|0 Reviews

ITC-18/USB 16 bit data acquisition interface

AutoMate Scientific Inc.

The ITC-18 is the second-generation low-noise 16-bit computer interface from Instrutech Corporation. The ITC-18 offers unsurpassed capability while retaining all of the exceptional features of its predecessor, the ITC-16. The ITC-18 provides a major improvement in the quality of acquired data, making measurements that would otherwise not be possible.* All synchronous analog and digital channels are optically isolated* Eight si…

0.0/5.0
|0 Reviews

MultiClamp 700B current & patch clamp amplifier

AutoMate Scientific Inc.

Computer-controlled microelectrode amplifier with a high-speed current clamp capable of sharp-electrode, field potential or ion-selective measurements, and a patch clamp for whole-cell, excised or cell-attached patches, bilayers, and electrochemistry with voltammetry or amperometry. MultiClamp 700B is shipped with the following,MultiClamp 700B Amplifiero Two 1-CV-7B headstageso US power cord (Part Number 1-3010-0011)o Europea…

0.0/5.0
|0 Reviews

Port-a-Patch® set up with MultiClamp Amplifier

AutoMate Scientific Inc.

The world's smallest patch clamp rig. Providing biggest results. The Port-a-Patch is a one-cell-at-a-time system, which is surprisingly small for a complete patch clamp rig. Patch clamp recordings in the whole cell configuration, and single channel recordings in the cell attached configuration, can be performed with planar patch clamp chips. The Port-a-Patch is routinely provided with an Axon/MDC MultiClamp amplifier or an EPC…

0.0/5.0
|0 Reviews

ChannelMAX 100A Twin Automated Patch Manipulators

AutoMate Scientific Inc.

Run dual two-electrode voltage clamp experiments simultaneously:With two additional micromanipulators, the system can perform dual two-electrode voltage clamp (TEVC) experiments simultaneously. Designed to be affordable to the scientific community, this system increases productivity significantly. Additional units can be run in parallel to further increase TEVC throughput.Run up to four patch clamp simultaneously:As each man…

0.0/5.0
|0 Reviews

ez-gSEAL 100A Patch Pressure Controller

AutoMate Scientific Inc.

The ez-gSEAL 100A pressure controller is designed mainly for automated patch clamping, but it can also be used for many other applications. With the ez-gSEAL pressure controller, patch clamping becomes as easy as a click of a button. You may use it with our ezPATCH 100A smart manipulator, PatchMAX 100A automated patch clamp system, ChannelMAX 100A Mini automated dual clamp system or ChannelMAX 100A Twin automated quad clamp sy…

0.0/5.0
|0 Reviews

PatchMAX 100A Automated Patch Manipulator

AutoMate Scientific Inc.

Incredibly small footprint:This patent-pending design has an 8" x 8" footprint; it is the smallest multifunction patch clamp system available.  The automated patch clamping system replaces the microscope and the manipulator in the traditional rig. Complete with one automated manipulator, a manual XY stage, a data acquisition board & control system, and a perfusion chamber with the platform, this system can automatically guide…

0.0/5.0
|0 Reviews


Open Oocyte Perfusion Chamber w/100mm adapter

AutoMate Scientific Inc.

* Small working volume (* Fast solution exchangeExpression of recombinant receptors in oocytes has been a favorite choice for researchers to assess the pharmacology of recombinant receptors. Since the oocytes are 1-1.5 mm in diameter, however, fast solution exchange around the oocyte was difficult. After several years of electrophysiological research, we have designed a Xenopus oocyte perfusion chamber for use in automated and…

0.0/5.0
|0 Reviews


pCLAMP 10 Standard Electrophysiology software (Windows)

AutoMate Scientific Inc.

Comprehensive electrophysiology data acquisition and analysis software. Provides both sweep-oriented stimulation and continuous data acquisition along with online analysis. Analyses all types of data: patch-clamp I-V, action potentials, minis and single-channel. Includes graphing and layout capability. pCLAMP 10 is shipped with the following:o pCLAMP 10 CD (Part number 1-2700-0167)o pCLAMP 10 USB security key (Part number 1…