860 KF Thermoprep

Thermal sample preparation in Karl Fischer titration. For various reasons many substances are not suitable for a direct Karl Fischer titration: – They release their water only slowly – The water is released at high temperatures only – The substances are poorly soluble in alcohols – They undergo side reactions with KF reagents – They contaminate the titration cell or the electrodes By using the KF oven method the above-mentio…

Request Pricing
Metrohm AG

Receive your quote directly from the manufacturer.

Reviews

Average Rating 4.3

|1Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Rápido y fiable Fast & Reliable

 

Average Rating 4.3

Application Area:

Contenido en agua en aceite lubricante usado Water content in used lubricating oil

Equipo fácil de usar e intuitivo. Logramos resultados fiables, repetitivos y reproducibles, testado con material de referencia. Al principio cuesta un poco elegir la temperatura de ensayo y peso idóneo de muestreo para nuestro rango de trabajo, pero una vez configurado el equipo el manejo es super rápido. Si las muestras son susceptibles de tener un alto contenido en agua el tiempo de ensayo es muy alto, para contenidos en agua en torno a 500 ppm a 140ºC el tiempo se ensayo es de unos 30 min aprox. Una vez finalizada la medida el equipo te avisa con un sonido, es muy práctico, porque puedes hacer otras actividades mientras el equipo está midiendo. Easy-to-use and intuitive equipment. We achieve reliable, repetitive and reproducible results, tested with reference material. At first it is a bit difficult to choose the ideal test temperature and sampling weight for our working range, but once the equipment is configured, the handling is super fast. If the samples are likely to have a high water content the test time is very high, for water contents around 500 ppm at 140ºC the test time is about 30 min. Once the measurement is finished, the equipment warns you with a sound, it is very practical, because you can do other activities while the equipment is measuring.

Review Date: 27 Nov 2023 | Metrohm AG

Thermal sample preparation in Karl Fischer titration.

For various reasons many substances are not suitable for a direct Karl Fischer titration:

– They release their water only slowly
– The water is released at high temperatures only
– The substances are poorly soluble in alcohols
– They undergo side reactions with KF reagents
– They contaminate the titration cell or the electrodes

By using the KF oven method the above-mentioned problems can be avoided. The substance under investigation is heated in a hermetically sealed vial in the oven. The water vapor released is transferred to the titration cell by a carrier gas. This means that no noxious solubilizers have to be used, side reactions as well as matrix effects are absent and the contamination of the titration cell is avoided.

Depending on the sample’s water content, the determination can be carried out either by coulometric or volumetric Karl Fischer titration.

Product Overview