Top Tips for LC-MS Sample Preparation

1 Jul 2015
Lois Manton-O'Byrne, PhD
Executive Editor

Editorial article

Dr Vivek Joshi Vivek Joshi, Ph.D. is a Principal Research Scientist at EMD Millipore, developing new products and applications for pharmaceutical, industrial, food/beverage and environmental monitoring laboratories. Prior to joining EMD Millipore, Dr. Joshi worked on high throughput LC-MS applications at ArQule and his doctoral research focused on molecularly imprinted polymers (MIPs).

At the 63rd ASMS, held in St Louis, MO, USA, Dr. Vivek Joshi, Principal Research Scientist at EMD Millipore, discussed everything you need to know to be an LC-MS expert. In an exclusive interview after his seminar, Dr. Joshi revealed how to avoid common mistakes when preparing samples for LC-MS and how to optimize your method to collect the highest quality data.

Read on for tips on sample preparation, streamlining your workflow and choosing the best column for the job.

Streamline your workflow

The three main points when looking at streamlining your LC-MS workflow are sample preparation, choice of mobile phase and choice of column. Neglecting any of these will negatively affect your data, but spending too long on them can slow you down. With run times becoming increasingly shorter, sample preparation can become the new bottleneck, hence it makes sense to do the minimum sample preparation which gives you the results you are looking for. Just by paying attention to quality of mobile phase ingredients, overall analytical performance can be improved. Finally selecting the right column type will provide the data a scientist is looking for.

Understand your sample

Before you start, it is very important to understand the type of analyte you are working with and its physical characteristics, as they will determine your method of sample preparation, the components of your mobile phase, and the type and selectivity of your column; for example, whether it is hydrophobic or hydrophilic, soluble or not etc. In some cases, you also need to think about other matrix components that are present in your sample and can interfere with the analyte of interest. Sample preparation and appropriate column selection can help with these interfering matrix components.

Optimize sample preparation

Once you have identified the needs of your analyte, you can start preparing it for analysis. The main goal of sample preparation is to bring sample to a form which is amenable to downstream HPLC analysis. That means at a bare minimum the sample is dissolved in a solvent and free of particles. However, depending on the analysis needs, more complex sample preparation will need to be done which not only removes the particles but also removes soluble interfering matrix components. Some parts of the sample preparation can be automated to reduce overall time required for sample preparation.

Prioritize filtration

Filtration is one of the most common steps in the preparation of an analyte for LC-MS, usually to remove any particles from the sample. However, the buffer solution can also introduce particles, from undissolved salts, and other contamination can be introduced from the solvent used in the sample preparation or even during the LC-MS run. Although LC-MS grade solvents are filtered and packed under an inert atmosphere, the laboratories where they are used are seldom completely clean. Dr Joshi recommends filtering everything, from sample to mobile phase, instead of relying on the cleanliness of the tubes and bottles used during the solvent transfer.

Pick your filtration membrane wisely

With all the additional filtering you'll now be doing, it's more important than ever to use the appropriate filtration membrane. Each different process used by manufacturers gives membrane with slightly different morphologies and pore sizes, but Dr Joshi recommends a filter made from hydrophilic PTFE membrane. Hydrophilic PTFE has broad chemical compatibility with very low extractables and analyte binding, allowing the majority of the sample to be recovered and with minimum additional contamination.

Use the most appropriate mobile phase

When making up your mobile phase, always use the highest grade solvents and reagents possible. Buffer salts used in LC-MS work flow have to be volatile, as non-volatile salts can precipitate out in the MS. Every mobile phase component in your LC-MS run (water, solvents and buffer salts) contributes to your background signal, and a high level of background noise will negatively affect your limit of detection (LOD) and limit of quantification (LOQ).

Don't rely on manufacturers

However, even hyper- or LC-MC-grade solvents can contain some contaminants, and each manufacturer will use a slightly different method of production, which will vary the nature and levels of contamination. Some solvents, such as butanol, aren't available in the higher grades, so will need to be filtered and purified in the lab before your LC-MS can be carried out.

Minimize contamination

Once you have filtered your solvents completely, try to use them straight away. Storing them can lead to leaching of contaminants from the storage container. Incomplete removal of particles from the components of the mobile phase can also lead to increased back pressure during a HPLC run, which in turn can shorten the life of your column or lead to system shut down during a critical sample run because of excess backpressure.

Choose your column

As technology progresses from HPLC to UHPLC, the separation efficiency and lifetime of the column is increasingly affected by packing type. Monolith-type columns offer the highest efficiency with the lowest necessary sample preparation and the lowest back pressure. Their particle-free design is less likely to become blogged, improving their robustness and subsequently their lifetime. They are therefore ideal for high-throughput operation, improving the efficiency of any lab.

Learn more about HPLC and choosing a column with our exclusive Buying Guide.

Links

Tags

UHPLC and HPLCHigh performance liquid chromatography (HPLC) and ultra high performance liquid chromatography (UHPLC), also known as UPLC, are analytical techniques used to separate, identify and quantitate components of complex mixtures including biological samples such as proteins and lipids as well as chemical mixtures of pesticides, drugs and oils. Both techniques are liquid chromatographic methods but differ by operating pressures (HPLC < 6000 psi < UHPLC ). Components of HPLC and UHPLC systems include columns, detectors, pumps, autosamplers and column heaters. Explore a range of UHPLC and HPLC columns for your specific sample needs including reverse phase, normal phase, ion exchange, HILIC, ion exclusion and size exclusion columns. For more specialized HPLC, explore FPLC, countercurrent LC and simulated moving bed systems. Find the best UHPLC and HPLC equipment in our peer reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Sample PreparationSample preparation can improve the quality and speed of separation techniques. Products to assist sample preparation include filtration equipment, evaporators, membranes and sieves.LC-MSLC-MS (liquid chromatography-mass spectrometry) systems and equipment are used for separation and quantitative analysis of complex mixtures, combining liquid chromatography and mass spectrometry. Quantify proteins, contaminants, pesticides or screen for drug metabolites with a high level of sensitivity. LC-MS systems and equipment include reverse phase, normal phase and specialized columns integrated with various MS detectors such as time-of-flight (TOF), quadrupole, orbitrap or ion trap mass analyzers. LC-MS/MS instruments equipped with a qTOF or triple quadrupole analyzer give greater sensitivity and resolving power to your analysis. Find the best LC-MS equipment in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Mass SpectrometryMass spectrometry (MS) is a powerful analytical technique used to identify and quantify molecules based on the mass-to-charge ratio of gas-phase ions. It provides detailed information about the structure, composition, and properties of compounds and is widely used across fields such as environmental monitoring, materials science, drug discovery and development, food and beverage testing, and wider chemical research. Key MS techniques include tandem mass spectrometry (MS/MS), liquid chromatography–mass spectrometry (LS-MS) and inductively coupled plasma (ICP-MS). Choosing from these wide range of techniques and technologies can be a daunting task, so keep up to date with scientific applications, performance expectations, and customer reviews here all in one place. Visit our product directory to receive quotes direct from the manufacturer. Clinical ChemistryBiochemistry (or clinical chemistry) involves the analysis of bodily fluids using chemical tests. Techniques used include HPLC, chromatography, spectroscopy, mass spectrometry, immunochemical, electrophoresis, turbidometric / spectrophotometric assay, MRI and ISE analysis. Tests are often carried out on plasma or serum but urine (urinalysis) and fecal specimens are also processed.Clinical Mass SpectrometryMass spectrometry is emerging as a superior method of analysis over the longstanding, gold standard of immunoassay. Clinical mass spectrometry systems are increasingly accessible to medical laboratories and are capable of providing results with more speed and less expense than traditional methods. From simple mass spectrometers to IVDR class A compliant, highly sophisticated systems performing liquid chromatography tandem mass spectrometry (LC/MS/MS), find the latest product news, reviews and resources to make a purchasing decision for your laboratory. ASMSThe American Society for Mass Spectrometry (ASMS) is an organization dedicated to advancing the science and application of mass spectrometry. ASMS supports professionals through events, publications, and research initiatives, promoting innovation in areas like proteomics, metabolomics, and environmental analysis. LC-MSLiquid Chromatography-Mass Spectrometry (LCMS) is a powerful analytical technique that combines the separation power of liquid chromatography with the detection capabilities of mass spectrometry. It is widely used for qualitative and quantitative analysis of complex mixtures in pharmaceuticals, proteomics, and environmental studies. Browse our peer-reviewed product directory to find the best LCMS systems, compare products, check reviews, and get pricing directly from manufacturers.