Shimadzu's CHIP-1000 and AXIMA MALDI-MS Combine Their Strengths for MALDI Tissue Imaging Experiments

16 Oct 2007
Greg Smith
Analyst / Analytical Chemist

Product news

Shimadzu, one of the world's leading developers of analytical instrumentation, drives the development in the fast growing field of direct tissue analysis by MALDI-MS to identify potential biomarkers or to control compound distribution. In general, these applications have so far suffered from low reproducibility and a slightly inaccurate delivery of solvents for sample pretreatment. The combination of Shimadzu's CHIP-1000 for fast reproducible sample preparation and the AXIMA MALDI-MS systems for data acquisition will give this field a new momentum.

Fast reproducible sample preparation
The CHIP-1000 is a unique device employing state-of-the-art chemical printing technology for delivering reagents on a micro-scale using piezo-electric technology. Each droplet volume is less than 100 pL. MALDI matrix is precisely delivered to specific surface locations via a non-contacting spotting method to minimize the possiblity of contamination.

Matrix can be automatically and reproducibly deposited directly onto pre-selected regions of a tissue surface. Large matrix arrays can be generated to cover the entire surface of tissue sections (imaging) or smaller arrays can be used to study the differences between a number of different areas within the tissue (profiling). Due to its highly accurate delivery system, enzymatic digestions can also be carried out prior to matrix printing, enabling the identification of proteins by MS/MS sequence analysis. The easy and fast operation allows the user to screen different matrix, enzyme or solvent conditions in profiling mode to get the most out of one tissue section.

The CHIP-1000 incorporates a camera and an onboard scanner. The camera serves to optimize and monitor droplet formation, while the visible light scanner is used to identify target areas on the tissue surface for reagent delivery, improve visualization of the deposited arrays and create a target map for printing.

The CHIP-1000 also has an image import functionality. This enables tissue images to be imported from other scanning devices and superimposed to thie tissue image on the MALDI plate. The CHIP-1000 facilitates the simple transfer of spotted sample locations to the AXIMA™ MALDI mass spectrometer for mass spectral data acquisition. In addition, it can also export the coordinates of print positions to other formats.

Sensitive and flexible data acquisition
The AXIMA series offers sensitive and flexible MALDI mass spectrometry ideal for imaging and profiling experiments. All AXIMA systems can be seamlessly integrated into a tissue imaging/biomarker discovery workflow. Using unique CHIP-1000 Imaging Experiment software, each print array can be seamlessly configured for data acquisition. A simple stage alignment procedure and highly accurate stage motors ensure that the laser fires precisely at each of the matrix spots deposited – crucial, considering each matrix spot can be <200 microns in diameter.

The advanced laser technology ensures averaged intensities across each print position by roaming within a set print position. A variety of different sample targets and adaptors can be used, including microscope format MALDI targets suitable for clinical applications. Plate files and methods for data acquisition are automatically generated using the information provided by the CHIP-1000 and spectra can be generated over a mass range of interest.

Peptides, proteins or other small molecules, for example drugs and their metabolites, can be analyzed directly from the tissue surface allowing the user to determine the distribution of the target compound within the sample. In addition to Shimadzu's software tools for direct visualization of the results, the data can be exported to the well known BioMAP software.

Tags

Mass SpectrometryMass spectrometry (MS) is a powerful analytical technique used to identify and quantify molecules based on the mass-to-charge ratio of gas-phase ions. It provides detailed information about the structure, composition, and properties of compounds and is widely used across fields such as environmental monitoring, materials science, drug discovery and development, food and beverage testing, and wider chemical research. Key MS techniques include tandem mass spectrometry (MS/MS), liquid chromatography–mass spectrometry (LS-MS) and inductively coupled plasma (ICP-MS). Choosing from these wide range of techniques and technologies can be a daunting task, so keep up to date with scientific applications, performance expectations, and customer reviews here all in one place. Visit our product directory to receive quotes direct from the manufacturer. MALDI-TOF MSMALDI-TOF mass spectrometers (matrix-assisted laser desorption/ionization time-of-flight) are used for the mass analysis of large molecules, including proteins, DNA, polymers and other macromolecules due to its relatively soft ionization, reducing fragmentation whilst allowing fast data acquisition. Tandem mass analyzers such as TOF/TOF systems can be used to increase resolution and sensitivity of your analysis. Find the best MALDI-TOF products in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.BiomarkersBiomarkers are biological markers which can be measured and evaluated to indicate a biological state. The use of biomarkers in research and diagnosis can indicate a normal or disease state or drug response of cells / tissues. Biomarkers include genetic markers, cell surface markers such as antigens, antibodies or receptors and secreted molecules such as cytokines. An assay system is required for identification of biomarkers. :