New Standard Test Method to Assess Water Safety

24 Jan 2017
Mia Harley
Biochemist

Industry news

Researchers investigating nutrient runoff, and water quality and wastewater treatment operators can now benefit from a new American Society for Testing and Materials (ASTM) standard that utilizes the powerful separation capabilities of ion chromatography for the simultaneous determination of total nitrogen and phosphorous concentrations.

Developed in conjunction with the ASTM, the “D8001 Test Method for Determination of Total Nitrogen, Total Kjeldahl Nitrogen by Calculation, and Total Phosphorus in Water and Waste Water by Ion Chromatography” allows users to concurrently monitor total nitrogen (organic nitrogen, ammonia, nitrate and nitrite) as nitrate and total phosphorus as orthophosphate in unfiltered water samples.

“Thermo Fisher’s method provides a single, reliable instrumental method for the determination of the target analytes in water, in place of traditional multiple and complex wet chemical methods, with the opportunity for accumulative errors,” said Robert Joyce, chairman of the ASTM International Subcommittee D19.06. “We expect the method should deliver labor savings, as well as improved sensitivity and accuracy.”

Currently, laboratories use two methods to determine total kjeldahl nitrogen (TKN) and total phosphate. The new test method can be incorporated into existing ion chromatography protocols with the addition of a single sample digestion and analysis step to determine total nitrogen and total phosphate simultaneously. By comparing digested and undigested samples using this method, the tedious TKN digestion method can be eliminated—ultimately saving time, disposal costs of acidic reagents and reducing some of the known false positives from TKN that occur with the use of acidic reagents.

“Excess amounts of essential nutrients such as nitrogen and phosphorous can cause algal blooms, leading to the generation of toxic microcystins,” said Richard Jack, senior director, Environmental and Industrial marketing, Chromatography and Mass Spectrometry, Thermo Fisher Scientific and ASTM member. “With this new method, scientists should be able to identify excess nutrients in waterways from water treatment and agricultural runoffs.”

The new method involves a simple two-step process, sample digestion and analysis. During the digestion step, a water sample is digested with alkaline persulfate, which results in oxidation of nitrogen compounds to nitrate and hydrolysis of phosphorus to orthophosphate. Following this, the sample can be analyzed using an ion chromatography platform, such as the Thermo Scientific™ Dionex Integrion HPIC system coupled with the Thermo Scientific™ Dionex™ Chromeleon™ 7.2 Chromatography Data System (CDS) software, to produce accurate and reproducible determination of nutrients at high throughputs.

Thermo Scientific™ Dionex™ Integrion™ HPIC™ System

Thermo Fisher Scientific

As an ion chromatographer, the routine IC applications you run give the rest of us the peace of mind to use everyday resources like water, food and beverages, biofuels and pharmaceuticals without a second thought. Using this high-pressure-capable IC system to separate and quantify common ionic pollutants in municipal drinking water and wastewater can provide faster, more cost-effective methods for regulatory compliance testing.   Nothing supports you in this role more than your laboratory instruments. The Thermo Scientific™ Dionex™ Integrion™ HPIC™ system is designed to be your reliable lab partner.     Features:   Simplified plumbing layout with integrated architecture - Layout based on logical flow-path for easy component access in a compact platform with a small physical footprint. Consumables Device Monitor - Provides positive identification of a consumable's performance metrics, preventing consumable installation errors and mismatches by automatically logging consumable use and performance. Detachable tablet with local language support - Flexible access to IC controls that speak your language Upgradeable features - In a fluid market with changing demands, the Dionex Integrion IC system offers a wide range of upgradable components, so it can grow with your needs over time. These include electrolytic sample preparation and electrolytic water purification Automated Eluent Generation (EG™) - Eliminate human errors associated with manual eluent preparation and improve method reproducibility from operator-to-operator and lab-to-lab. The Dionex Integrion IC system brings consistent results to all your applications. In this case, 100 injections of a simple sugar mixture are highly reproducible. Wide range of column support - Choose the column sizes you need for your applications, including smaller-particle-size 4 µm columns that provide faster run times and better resolution. Flexibility – two different models to choose from and option to choose right detector or column format for your application

(5)

Tags

Ion ChromatographyIon chromatography, also known as ion exchange chromatography, is a high-performance liquid chromatographic technique used for the separation and identification of ions or polar molecules in a sample, including proteins, nucleotides and amino acids. Equipment includes ion exchange columns, ion exclusion columns, ion chromatography systems, pumps, and detectors. Find the best ion chromatography equipment in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Data AnalysisData analysis hardware and software is available to make data processing straight-forward yet powerful. Data software can be used for math and stats, technical graphing and image analysis. In addition, software is available for specific data analysis of electrophoresis, densitometry, ELISA and DNA sequencing.Environmental Monitoring and TestingEnvironmental monitoring and testing uses handheld portable analyzers, kits, spectrometers or chromatography systems for air, water, soil, food and other sample testing. Useful features of analyzers such as BOD and COD include portability, easy calibration, automation and sensitivity.  Environmental test kits for pH, water, moisture, etc, should be accurate, sensitive, reliable, fast and easy to use.Water PurificationThere are a number of water purification methods available to remove contamination from laboratory water. These systems include demineralization, reverse osmosis, filtration and ultrafiltration. A combination of methods is sometimes necessary to achieve purified water suitable for use in experiments.Software PlatformsSoftware platforms are useful for various stages of laboratory experiments from data collection to data storage and processing. For instance lab software is available for system control, data management, data analysis and qualification / validation.Waste WaterWater AnalysisAnalytical methods used to test the purity of drinking water include determining the level of contaminants abides to the level set by the Environmental Protection Agency (EPA).Environmental ContaminationContaminants in the environment are harmful chemicals that are present in the air, land and water. These include pesticides, pharmaceuticals, persistent organic pollutants (POPs) and many more.Water Content AnalysisWater content analysis is crucial for determining the moisture levels in food, pharmaceuticals, chemicals, and other materials. Accurate measurement ensures product quality and shelf-life. Explore water content analysis tools in our peer-reviewed product directory; compare products, check reviews, and get pricing directly from manufacturers.