New GC Columns and Standards for Blood Alcohol Testing

21 Mar 2012
Roger Wayman
Administrator / Office Personnel

Product news

Restek has announced the release of new Rtx®-BAC Plus 1 and Rtx®-BAC Plus 2 columns for blood alcohol testing. These GC columns baseline separate all critical compounds, including ethanol, methanol, acetone, tert-butanol (IS), acetaldehyde, isopropanol, and 1-propanol (IS), in less than 2 minutes. Every column is quality tested with these important target compounds in order to ensure performance. Optimized column selectivity’s guarantee resolution of ethanol, internal standards, and frequently encountered interferences.

In addition to the GC columns, new BAC resolution control standards with either tert-butanol or 1-propanol internal standard are now available. These check standards are used to verify the retention time for each compound normally included in a blood alcohol test. They also are used to confirm that the analytes are well resolved from each other and do not interfere with one another.

New Rtx®-BAC Plus 1 and Rtx®-BAC Plus 2 columns and BAC resolution control standards are designed to provide definitive results quickly, allowing increased sample throughput for blood alcohol testing.

Rtx®-BAC Plus 1 Columns (fused silica)

Restek Corp.

Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. 2 minute analysis time increases lab productivity. Stable to 260 °C Don’t forget: Blood alcohol analysis requires dual column confirmation when using GC/FID.

(2)

Rtx®-BAC Plus 2 Columns (fused silica)

Restek Corp.

Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences. Robust and reproducible column chemistry ensures longer column lifetime and consistent results. 2 minute analysis time increases lab productivity. Stable to 260 °C Don’t forget: Blood alcohol analysis requires dual column confirmation when using GC/FID.

(2)

Links

Tags

Gas ChromatographyGas chromatography (GC) is an analytical technique used to separate and quantitate mixtures of small and volatile compounds. Gas chromatographs or GC systems include components such as GC columns, detectors, pumps and autosamplers. Choose from packed or capillary GC columns, flame ionization (FID), photoionization (PID) electron capture detectors and selective or non-selective detectors. Find the best gas chromatographs in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Clinical ChemistryBiochemistry (or clinical chemistry) involves the analysis of bodily fluids using chemical tests. Techniques used include HPLC, chromatography, spectroscopy, mass spectrometry, immunochemical, electrophoresis, turbidometric / spectrophotometric assay, MRI and ISE analysis. Tests are often carried out on plasma or serum but urine (urinalysis) and fecal specimens are also processed.BAC Testing