Wyatt Technology’s MALS instrument achieves ultimate purification of the Rab11-FIP2 Complex

3 Apr 2007

Product news

Explore the findings of analysis carried out by the School of Biochemistry and Immunology of the Trinity College in Dublin, Ireland that demonstrates that Wyatt Technology’s miniDAWN™ Multi-Angle Light Scattering (MALS) instrument measures the finest purification of the Rab11-FIP2 complex.

The small GTPase Rab11 regulates the recycling of endosomes to the plasma membrane via interactions with the Rab11 Family of Interacting Proteins (FIPs). FIPs contain a highly conserved Rab-Binding Domain (RBD) at their C-termini. The overall structure is a hetero-tetramer with dyad symmetry, arranged as a Rab11-(FIP2)2-Rab11 complex. FIP2 forms a central α-helical coiled-coil, with both helices contributing to the Rab11 binding patch on equivalent and opposite sides of the homodimer. The solution state of FIP2 needs to be characterized alone in order to confirm that Rab11 binds to a preformed complex of the FIP2 homodimer.

For this particular application, the constructs FIP2 were co-transformed into BL21 cells and over-expressed in 2xYT media supplemented with 100 mg/ml ampicillin and 30 mg/ml kanamycin at 37˚C. Following induction, cells were grown for a further 3h, harvested by centrifugation and stored at -20˚C. Frozen pellets were re-suspended in Maltose-Binding Protein (MBP) extraction buffer and sonicated at room temperature.

Cell lysates were centrifuged at 20,000g to remove cell debris and the resultant supernatant applied to an amylose resin. After extensive washing with MBP extraction buffer, bound protein was eluted with MBP elution buffer. Eluted protein was dialyzed overnight against 10mM Tris, 25mM NaCl in the presence of rTEV protease. Cleaved protein was loaded onto an ion-exchange column and a salt gradient was applied over a 20-fold excess column volume. The protein fractions corresponding to FIP2 were pooled and further purified on a superdex 200 16/60 column equilibrated in column buffer. The eluant was coupled to a miniDAWN and an Optilab RI.

The results of the analysis reveal that FIP2 is indeed a dimer in solution. Since Rab11 in solution is a monomer, the light scattering data suggest that FIP2 forms homodimers and recruits two molecules of Rab11 during trafficking of Rab11-positive endosomes.

For more information on Wyatt Technology’s miniDAWN™ MALS instrument or to obtain a copy of this application note, please visit the article webpage or click 'request info'.

Tags

UHPLC and HPLCHigh performance liquid chromatography (HPLC) and ultra high performance liquid chromatography (UHPLC), also known as UPLC, are analytical techniques used to separate, identify and quantitate components of complex mixtures including biological samples such as proteins and lipids as well as chemical mixtures of pesticides, drugs and oils. Both techniques are liquid chromatographic methods but differ by operating pressures (HPLC < 6000 psi < UHPLC ). Components of HPLC and UHPLC systems include columns, detectors, pumps, autosamplers and column heaters. Explore a range of UHPLC and HPLC columns for your specific sample needs including reverse phase, normal phase, ion exchange, HILIC, ion exclusion and size exclusion columns. For more specialized HPLC, explore FPLC, countercurrent LC and simulated moving bed systems. Find the best UHPLC and HPLC equipment in our peer reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.ProteomicsProteomics is the systemic bioinformatics study of proteins and amino acids, including their structure, size, function and identification. Tools used in proteomics include chromatography, blotting and gels, protein arrays, mass spectrometry and ELISA and associated analysis software. Analyzers and proteomic systems should be sensitive, high resolution, fast and may be automated for high-throughput.
Wyatt Technology’s MALS instrument achieves ultimate purification of the Rab11-FIP2 Complex