Abbott has announced that the ARCHITECT AFP test, which may help doctors detect serious birth defects and the progression of testicular cancer, received U.S. Food and Drug Administration (FDA) approval. Biomarkers, such as alpha-fetoprotein (AFP), are substances in the body that physicians can measure to identify the progress of diseases or conditions as well as to evaluate the effectiveness of treatments. AFP has unique traits that help doctors detect two very different health issues: fetal birth defects and the progression of testicular cancer.

AFP and Birth Defects
Neural tube defects (NTDs) are serious fetal birth defects of the brain and spine that occur very early in development. When the neural tube, a structure that develops into the brain and spinal cord, fails to close properly, AFP is thought to leak directly from the fetus into the mother’s amniotic fluid, causing unexpectedly high levels of AFP in the mother’s blood. A blood test that measures AFP can help doctors determine if a woman is carrying a fetus affected with birth defects, such as anencephaly (the absence of a large part of the brain and the skull) and spina bifida (the incomplete closing of the backbone and spinal canal). Treatments for NTDs focus on closing the defect with surgery (including surgery before birth) and treating or addressing related symptoms such as excess fluid in the brain and bladder and bowel problems.

AFP and Testicular Cancer
Men with one type of testicular cancer, called nonseminoma germ cell, have elevated AFP levels present in their bloodstreams. Blood tests to measure AFP can be used to evaluate responses to treatment. By monitoring disease progression and seeking treatment when necessary, testicular cancer can be a highly treatable and usually curable cancer.

"The ARCHITECT AFP assay is a valuable tool that will help physicians obtain reliable measurements of this protein for use in guiding critical patient treatment decisions," said Brian Blaser, executive vice president, Diagnostics Products, Abbott. "Abbott is pleased to offer this important assay to our customers to positively affect patient care."

About the ARCHITECT AFP Assay
The new assay runs on Abbott’s fully-automated ARCHITECT i2000, i2000SR, ci8200, and ci16200 analyzers, and is available in the United States, CE marked, and non-regulated countries.

Intended Use
The ARCHITECT AFP assay is a chemiluminescent microparticle immunoassay (CMIA) for the quantitative determination of alpha-fetoprotein (AFP) in:
1. Human serum or plasma to aid in monitoring disease progression during the course of disease and treatment of patients with nonseminomatous testicular cancer.
2. Human serum, plasma, and amniotic fluid at 15 to 21 weeks gestation to aid in the detection of fetal open neural tube defects (NTD). Test results when used in conjunction with ultrasonography or amniography are a safe and effective aid in the detection of fetal open NTD.

ARCHITECT c16000 Clinical Chemistry Analyzer

Abbott

ARCHITECT c16000 can be integrated with the ARCHITECT i2000SR to consolidate clinical chemistry and immunoassay on one platform. True Family Commonality Seamless transfer from system to system • Equivalent results across all ARCHITECT c Systems • Identical technology, reagents and assay protocols •Identical software that is intuitive to operate •Universal ARCHITECT sample carrier Integration Without Compromise A unique approach to consolidation • SmartWash technology ensures no clinically significant sample tube to tube carryover (less than 0.1 ppm) •Robotic Sample Handler (RSH) eliminates bottlenecks and prioritizes urgent requests •Immediate STAT processing for fast and consistent turnaround time •Up to 65 refrigerated reagent positions plus patented ISE (Na+, K+, and Cl-) •215 sample load capacity including 35 priority positions •Continuous sample access •Throughput of up to 1,800 clinical chemistry tests per hour Enhanced System and Assay Dynamics The latest in immunochemistry technology •FlexRate methodology extends linearities and avoids repeats •Integrated Chip Technology (ICT) delivers ISE (Na+, K+, and Cl-) analysis with minimal maintenance, low sample volume (15 uL), and within run precision of 1% or less •Liquid level sensing combined with pressure differential technology for enhanced bubble and clot detection monitors sample integrity

(3)

ARCHITECT c8000 Clinical Chemistry Analyzer

Abbott

ARCHITECT c8000 can be integrated with the ARCHITECT i2000SR to consolidate complex workloads of clinical chemistry and immunoassay testing on to one efficient platform. Our innovative integration solution for clinical chemistry testing helps you: •Report STAT results quickly using dedicated positions on a three-dimensional sample handler •Reduce repeats and reruns with FlexRate technology that extends linear ranges of enzymatic assays •Standardize processes through equivalent patient results and common consumables across all ARCHITECT c Systems •Improve workflow efficiency with a large load up capacity for samples and refrigerated reagents See how the ARCHITECT c8000 can increase your lab's performance by contacting your Abbott representative.

(12)

Links

Tags

MicroplatesMicroplates are multi-well plates used to increase the throughput of biological investigations. The number of wells microplates contain can range from 6 to 3243 wells, with the 96-well format being the most commonly used. Microplates can come tailored for a range of applications including cell culture, PCR, filtration, storage, non-binding surface, protein crystallization, as well as pre-coated, deep well and normal Standard microplates. Additionally, options for microplate colors include clear , black, white or black with clear bottom and white with clear bottom for absorbance microplate reader applications. Find the best microplates for your lab in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.ImmunologyImmunological techniques measure and characterize immune responses. Immunology kits and analysis systems often use techniques such as ELISA, radioimmunoassay (RIA) and immunodiffusion assays, Immunohistochemistry, and flow cytometry. Immunologists use equipment such as flow Cytometers, plate readers, plate washers and fluorescent microscopes.Clinical ChemistryBiochemistry (or clinical chemistry) involves the analysis of bodily fluids using chemical tests. Techniques used include HPLC, chromatography, spectroscopy, mass spectrometry, immunochemical, electrophoresis, turbidometric / spectrophotometric assay, MRI and ISE analysis. Tests are often carried out on plasma or serum but urine (urinalysis) and fecal specimens are also processed.ImmunoassayImmunoassays are laboratory tests that utilize antibody-antigen interactions to detect specific substances. They are widely used in diagnostics for detecting diseases, drug testing, and environmental monitoring. These assays offer rapid, sensitive, and precise detection of biomarkers, making them invaluable in clinical and research labs. Browse our peer-reviewed product directory to compare immunoassay systems, read user reviews, and get pricing directly from manufacturers.Cancer DiagnosticsThere are a wide variety of diagnostic tests for cancer available, and this range continues to expand as our knowledge of cancer improves. Current diagnostic methods include biopsy, imaging and blood tests for known biomarkers. New methods in research development include liquid biopsies and cancer breathalyzers.FDAThe Food and Drug Association (FDA) is an agency within the U.S. Department of Health and Human Services. Among other things, it is responsible for ensuring the safety, effectiveness and quality of drugs, vaccines and other biological products, and medical devices.