Biomonitoring has become an indispensable tool for studying occupational and environmental exposure to chemicals, including persistent organic pollutants (POPs). POPs are lipophilic compounds and tend to accumulate in the lipid stores of the body.

Adipose tissue is mostly constituted by lipids (generally about 95% of the tissue) and therefore the POPs are generally found at the highest levels in this tissue. Because of the invasive nature of the surgical procedure required to obtain the adipose tissue sample, the analytical community then turned their attention to developing methods in blood. This was a less invasive matrix, but the levels were much lower in the blood matrix due to the small amount of lipids (~0.6%) compared to adipose tissue (~95%). The methods required high resolution mass spectrometry (HRMS) in order to have the sensitivity required to measure normal background POPs levels in the picogram to femtogram range.

It is important to continue to try and develop more sensitive analytical methods for environmental chemicals: 1) to determine the normal human background levels of chemicals that we cannot detect with current methods; 2) to continue monitoring chemical levels that are decreasing in populations around the world (eg. dioxins, furans, PCBs, pesticides); 3) to provide better analytical CVs of chemicals that we can measure which will translate into lower measurement uncertainties; and 4) a lower analytical CV translates directly into higher statistical power in epidemiological studies.

Newer, more sensitive analytical techniques are currently being developed using cryogenic zone compression and loop modulation coupled with HRMS to measure POPs. A modification of this technique, called timed controlled cryogenic zone compression, is being developed by Thermo Scientific. This technique allows targeted cryofocusing of certain peaks that might need enhanced sensitivity, while allowing the remainder of the chromatographic separation to proceed unaltered.

The potential for these techniques to generate parts-per-quintillion detection are presented in a plenary lecture entitled ‘Human Biomonitoring: Parts per Quintillion— A New Frontier for Toxicologists and Risk Assessors’, by Donald G. Patterson Jr, Exponent, Inc.

View the plenary lecture.

Links

Tags

Mass SpectrometryMass spectrometry (MS) is a powerful analytical technique used to identify and quantify molecules based on the mass-to-charge ratio of gas-phase ions. It provides detailed information about the structure, composition, and properties of compounds and is widely used across fields such as environmental monitoring, materials science, drug discovery and development, food and beverage testing, and wider chemical research. Key MS techniques include tandem mass spectrometry (MS/MS), liquid chromatography–mass spectrometry (LS-MS) and inductively coupled plasma (ICP-MS). Choosing from these wide range of techniques and technologies can be a daunting task, so keep up to date with scientific applications, performance expectations, and customer reviews here all in one place. Visit our product directory to receive quotes direct from the manufacturer. ImmunologyImmunological techniques measure and characterize immune responses. Immunology kits and analysis systems often use techniques such as ELISA, radioimmunoassay (RIA) and immunodiffusion assays, Immunohistochemistry, and flow cytometry. Immunologists use equipment such as flow Cytometers, plate readers, plate washers and fluorescent microscopes.Environmental Monitoring and TestingEnvironmental monitoring and testing uses handheld portable analyzers, kits, spectrometers or chromatography systems for air, water, soil, food and other sample testing. Useful features of analyzers such as BOD and COD include portability, easy calibration, automation and sensitivity.  Environmental test kits for pH, water, moisture, etc, should be accurate, sensitive, reliable, fast and easy to use.Clinical ChemistryBiochemistry (or clinical chemistry) involves the analysis of bodily fluids using chemical tests. Techniques used include HPLC, chromatography, spectroscopy, mass spectrometry, immunochemical, electrophoresis, turbidometric / spectrophotometric assay, MRI and ISE analysis. Tests are often carried out on plasma or serum but urine (urinalysis) and fecal specimens are also processed.Clinical Mass SpectrometryMass spectrometry is emerging as a superior method of analysis over the longstanding, gold standard of immunoassay. Clinical mass spectrometry systems are increasingly accessible to medical laboratories and are capable of providing results with more speed and less expense than traditional methods. From simple mass spectrometers to IVDR class A compliant, highly sophisticated systems performing liquid chromatography tandem mass spectrometry (LC/MS/MS), find the latest product news, reviews and resources to make a purchasing decision for your laboratory. Persistent Organic Pollutants