Gentronix Launches New Genotoxic Metabolite Detection Assay

10 Mar 2008

Product news

Now available with an S9 protocol to detect genotoxic metabolites, GreenScreen HC from Gentronix is a human cell-based genotoxicity screening assay used in drug discovery programmes during lead compound optimisation and candidate selection.

Potential pharmaceutical compounds which only present a genotoxicity hazard after metabolism, usually by the liver, are known as pro-genotoxins. The utility of GreenScreen HC has now been extended to detect pro-genotoxins as well as all common mechanistic classes of genotoxin including mutagens, clastogens, aneugens, as well as both topoisomerase and polymerase inhibitors.

Using a standardized 96-well microplate format, the test compound and patented Green Fluorescent Protein (GFP) reporter cells are combined with 1% S9 for a 3 hour exposure period. After exposure, cells are washed to remove the S9 and test compound and then allowed a further 45 hour recovery incubation. Cell viability and GFP fluorescence data are assessed using flow cytometry and simple software generates quantitative results and a graphical output.

Minimal investment in early genotoxicity screening delivers major time savings, avoids unnecessary animal testing and prevents costly late stage failures of lead drug compounds through early detection of genotoxic potential. Combining exceptional levels of specificity and sensitivity, GreenScreen HC also correctly identifies non-carcinogenic compounds known to give misleading positive results in other in vitro genotoxicity assays.

GreenScreen HC

Gentronix Ltd.

Gentronix has launched a new, accurate and fast in vitro mammalian cell genotoxicity assay - GreenScreen HC. The TK6 host cells are p53 competent and familiar to most genetic toxicology laboratories. A patented GFP reporter system exploits the proper regulation of the GADD45a gene. The assay delivers both high specificity and high sensitivity and detects all common mechanistic classes of genotoxin. The 96-well microplate format takes about 20 minutes to prepare and delivers results after a 48 hour incubation. A single microplate is sufficient for the simultaneous testing of 4 compounds over 9 serial dilutions. The protocol is also readily automated using standard laboratory liquid-handling equipment. The Biology GADD45a mediates the adaptive response to genotoxic stress. The patented GFP fluorescence reporter includes complex regulatory elements. The assay gives positive results for direct acting agents, as well as aneugens, and topoisomerase and polymerase inhibitors. Importantly the assay gives correct negative results for non-carcinogens, including many which give misleading positive results in other in vitro tests. The Assay Protocol Nine, 2-fold dilutions of each compound together with positive controls are set out in the microplate and growing cells are added to each well. After incubation and measurement in a microplate reader, simple software gives automated decisions and a clear graphical output. Validation A unique combination of both high-specificity and high-sensitivity genotoxicity assessment in a human cell line has been demonstrated. See: High-specificity and high-sensitivity genotoxicity assessment in a human cell line: Validation of the GreenScreen HC GADD45a-GFP genotoxicity assay. Hastwell P.W. et al (2006) Mutation Research 607: 160-175.

(0)

Links

Tags

High-Throughput ScreeningHigh-throughput screening (HTS) is an automated drug discovery technique for identification of active compounds against a compound library. Use HTS readers and integrated assay preparation / analysis workstations to screen your compounds. Identify active compounds against various HTS libraries, including membranes, proteins and peptides and HTS cell lines. Find the best high-throughput screening products in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.ADME-ToxicologyADME-toxicology (ADME-Tox) studies are used in pharmacology and pharmacokinetics to assess the activity/toxicity of drugs <i>in vivo</i> or <i>in vitro</i>. Find bioassays for absorption, distribution, metabolism, and excretion of drug molecules including cytotoxicity, transporter/permeability, metabolism and activity assays as well as hepatocytes and cell lines for ADME. Find the best ADME-toxicology products in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Flow Cytometry / Cell CountingFlow cytometers are used to count, sort and examine multiple characteristics of cells. Other cell analysis equipment includes image cytometers, cell counters, fluorescence-activated cell sorters (FACS), magnetic-activated cell sorters (MACS), and a range of flow cytometry assay kits. Flow cytometers can reveal information on cell viability, cell proliferation, apoptosis and cell cycle progression, as well as identify cell populations and intracellular or cell-surface molecules. Additionally, some flow cytometers, known as FACS, have an additional sorting function after analysis. Cell counters and image cytometers count live and dead cell populations and can also conduct cell proliferation assays. Find the best flow cytometers, cell counters and cell sorters in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.