Cerno Bioscience Demonstrates New MassWorks sCLIPS for High Resolution FT-ICR Mass Spectrometers

14 Mar 2008
Greg Smith
Analyst / Analytical Chemist

Product news

Cerno Bioscience, in co-operation with Dr. Vladimir Tolstikov at the Genome Center, UC Davis, has demonstrated that the recently launched MassWorks™ sCLIPS™ (self Calibrated Line-shape Isotope Profile Search) capability significantly improves formula ID on high end FT-ICR MS systems. By using Cerno’s patented calibration techniques, users of High Mass Accuracy (HMA) instruments can now dramatically improve the results of formula identification and easily obtain higher quality, reproducible data through accurate line-shape calibration.

Using MassWorks sCLIPS, the latest addition to the MassWorks mass spectrometry software suite, the collaborative research was able to further improve formula ID by the use of Spectral Accuracy and thus help achieve unique formula determination. MassWorks was originally launched in 2006, and received the prestigious Editors’ Choice Bronze Award at PITTCON 2006. MassWorks is an easy-to-use post acquisition software system using Cerno’s patented MS Integrity calibration technology to work directly with data from a wide range of mass spectrometers.

Formula ID normally requires accurate mass measurements typically provided by high resolution Time-of-Flight (TOF), Orbitrap or FT-ICR instrumentation. With its resolving power reaching into 1,000,000:1, an FT-ICR instrument is capable of sub-ppm mass accuracy, a level considered sufficient by most high end users. However, where true unknown formula ID is required in applications such as natural product or metabolomics research, even such impressive levels of mass accuracy could lead to many possible formulas, especially at masses of 400Da or above. “How to go beyond mass accuracy and determine the correct formula amongst the many possible candidates becomes a problem crying out for a solution”, remarked Dr. Tolstikov, Director of Metabolomic Core Facility at UC Davis, and a long time user of Thermo Scientific FT-ICR MS. Cerno’s sCLIPS technology, when applied to FT-ICR MS data, corrects the instrument line-shape and enables exact isotope modeling when comparing the MS response of an unknown ion against theoretically calculated responses for all possible candidate formulas. This allows spectral differences as small as 0.1% to be measured which enables highly confident formula ID. One of the benefits of the approach is that it requires no known calibration ions, and instead utilizes the fully resolved monoisotopic peak of the unknown ion itself for the sCLIPS line-shape calibration.

Don Kuehl, VP of Product Development and Marketing for Cerno Bioscience comments, “This exciting new development further demonstrates the unique advantage of our line-shape calibration technology and the added power of Spectral Accuracy beyond mass accuracy. The new MassWorks software allows us to serve a broad range of MS markets, from the low end single quadrupole LC and GC/MS all the way up to the high end FT-ICR MS.”

Links

Tags

LC-MSLC-MS (liquid chromatography-mass spectrometry) systems and equipment are used for separation and quantitative analysis of complex mixtures, combining liquid chromatography and mass spectrometry. Quantify proteins, contaminants, pesticides or screen for drug metabolites with a high level of sensitivity. LC-MS systems and equipment include reverse phase, normal phase and specialized columns integrated with various MS detectors such as time-of-flight (TOF), quadrupole, orbitrap or ion trap mass analyzers. LC-MS/MS instruments equipped with a qTOF or triple quadrupole analyzer give greater sensitivity and resolving power to your analysis. Find the best LC-MS equipment in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.Mass SpectrometryMass spectrometry (MS) is a powerful analytical technique used to identify and quantify molecules based on the mass-to-charge ratio of gas-phase ions. It provides detailed information about the structure, composition, and properties of compounds and is widely used across fields such as environmental monitoring, materials science, drug discovery and development, food and beverage testing, and wider chemical research. Key MS techniques include tandem mass spectrometry (MS/MS), liquid chromatography–mass spectrometry (LS-MS) and inductively coupled plasma (ICP-MS). Choosing from these wide range of techniques and technologies can be a daunting task, so keep up to date with scientific applications, performance expectations, and customer reviews here all in one place. Visit our product directory to receive quotes direct from the manufacturer. Data AnalysisData analysis hardware and software is available to make data processing straight-forward yet powerful. Data software can be used for math and stats, technical graphing and image analysis. In addition, software is available for specific data analysis of electrophoresis, densitometry, ELISA and DNA sequencing.GC-MS GC-MS (gas chromatography-mass spectrometry) instruments and equipment are used to separate, quantify and identify mixtures of small and volatile compounds, such as polycyclic aromatics, fatty acids and alcohols. Often used in drug detection, forensic investigation and environmental analysis for pesticides and contaminants, GC-MS is a powerful addition to your lab’s analytical capabilities. GC-MS/MS instruments equipped with a qTOF or triple quadrupole analyzers can give greater sensitivity and resolution to your analysis. Find the best GC-MS instruments and equipment in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.